Measures against Thread Breakage
View all Brother International BES-1240BC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 197 highlights
Chapter 7 Operation of Machine 4. Measures against Thread Breakage 4-1 Remedies 1. If embroidering is suspended due to thread breakage, the THREAD SENSOR lamp of the machine head with a thread breakage blinks. 2. Correct the broken thread and pass it through again. * Refer to "Chapter 2, 3-1 Upper Threading" for details. 3. Press the STOP switch or press the STEP BACK/FWD switch in order to reset the alarm. THREAD SENSOR lamp HEAD switch MENDING lamp MENDING switch STEP BACK/ FWD switch STOP 4. Return the hoop to a position where thread breakage occurred by pressing the STEP BACK switch. or Note) When the switch is turned for 20 stitches or more, the machine continues operation without holding the switch. To stop the machine, turn the switch to the opposite side. 5. Press the START switch on the operation panel or the start switch located between the machine heads to resume operation. or START BES-940BC • BES-1240BC 195