Brother International PT-P900 P-touch Template Manual/ Command Reference - Page 42
^PS Specify print start command text string
View all Brother International PT-P900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 42 highlights
P-touch Template Command Reference ^PS Specify print start command text string ASCII: ^ P S n1 n2 Decimal: 94 80 83 nd1 nd2 Hexadecimal: 5E 50 53 nh1 nh2 data datad datah Parameters 0≤n1≤2 0≤n2≤9 00h≤data≤FFh Description Specifies the text string for the print start command. (n1*10)+n2: Length of the text string (can be set between 1 and 20) data: Text string (The maximum number of characters that can be set is 20 characters (bytes).) The default text string for the print start command is "^FF". This command is a dynamic command. Remarks Invalid if more than 20 characters have been specified Example To change the text string for the print start command to "START": Since the text string to be specified (data), "START", contains 5 characters, n1=0 and n2=5. Therefore, the command will be as follows. ^ P S05START (5Eh 50h 53h 30h 35h 53h 54h 41h 52h 54h) - 36 - 7. Control Command Details