Brother International PT-P900 P-touch Template Manual/ Command Reference - Page 48
^RC Specify line feed command text string
View all Brother International PT-P900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 48 highlights
P-touch Template Command Reference ^RC Specify line feed command text string ASCII: ^ R C n1 n2 Decimal: 94 82 67 nd1 nd2 Hexadecimal: 5E 52 43 nh1 nh2 data datad datah Parameters 0≤n1≤2 0≤n2≤9 00h≤datah≤FFh Description Specifies the text string for the line feed command. (n1*10)+n2: Length of the text string (can be set between 1 and 20) data: Text string (The maximum number of characters that can be set is 20 characters (bytes).) The default text string for the line feed command is "^CR". This command is a dynamic command. Remarks Invalid if more than 20 characters are specified Example To change the text string for the line feed command to "0Dh 0Ah": Since the text string to be specified (data) contains 2 characters, n1=0 and n2=2. Therefore, the command will be as follows. ^ R C 0 2 0Dh 0Ah (5Eh 52h 43h 30h 32h 0Dh 0Ah) - 42 - 7. Control Command Details