Brother International PT-P900 P-touch Template Manual/ Command Reference - Page 76

ESC iXD2 Specify delimiter

Page 76 highlights

P-touch Template Command Reference ESC iXD2 Specify delimiter ASCII: ESC i X D Decimal: 27 105 88 68 Hexadecimal: 1B 69 58 44 2 n1 n2 data 50 nd1 nd2 datad 32 nh1 nh2 datah Parameters 01h≤nh1≤14h nh2: 00h (FIxed) 00h≤datah≤FFh Description  The delimiter is used to indicate when to move to the next object in data that is being sent.  Specifies the text string for the delimiter. nh1+(nh2*256): Length of the text string (between 1 and 20) data: Text string (The maximum number of characters that can be set is 20 characters (bytes).)  The default text string for the delimiter is "09h" (TAB code).  This command is a static command. Remarks  Invalid if more than 20 characters are specified Example  To change the delimiter to "," (2Ch): Since the text string contains one character, nh1=01h and nh2=00h and, with the text string (datah) "," (2Ch), the command will be as follows. ESC i X D 2 01h 00h 2Ch (1Bh 69h 58h 44h 32h 01h 00h 2Ch) - 70 - 7. Control Command Details

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120

P-touch Template Command Reference
- 70 -
7.
Control Command Details
ESC iXD2 Specify delimiter
ASCII:
ESC i
X
D
2
n1
n2
data
Decimal:
27
105 88
68
50 nd1 nd2 datad
Hexadecimal: 1B
69
58
44
32 nh1 nh2 datah
Parameters
01h
nh1
14h
nh2: 00h (FIxed)
00h
datah
FFh
Description
The delimiter is used to indicate when to move to the next object in data that is being sent.
Specifies the text string for the delimiter.
nh1+(nh2*256):
Length of the text string (between 1 and 20)
data:
Text string (The maximum number of characters that can be set is 20 characters
(bytes).)
The default text string for the delimiter is “09h” (TAB code).
This command is a static command.
Remarks
Invalid if more than 20 characters are specified
Example
To change the delimiter to “,” (2Ch):
Since the text string contains one character, nh1=01h and nh2=00h and, with the text string (datah) “,”
(2Ch), the command will be as follows.
ESC i X D 2 01h 00h 2Ch
(1Bh 69h 58h 44h 32h 01h 00h 2Ch)