Brother International PT-P900 P-touch Template Manual/ Command Reference - Page 79
ESC iXn2 Select template
View all Brother International PT-P900 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
P-touch Template Command Reference ESC iXn2 Select template ASCII: ESC i X n 2 n1 n2 n3 Decimal: 27 105 88 110 50 nd1 nd2 nd3 Hexadecimal: 1B 69 58 6E 32 nh1 nh2 nh3 Parameters nh1: 01h (Fixed) nh2: 00h (Fixed) 01h≤nh3≤63h Description Specifies the number of the template selected from the machine. n3: Template number (1 to 99) The default selection number is 1. This command is a static command. Remarks The template numbers that can be set are between 1 and 99. This command becomes invalid if any other value has been specified or if the number that has been specified is of a template not transferred to the machine. Example To select template number 99: Since nh3=63h, the command will be as follows. ESC i X n 2 01h 00h 63h (1Bh 69h 58h 6Eh 32h 01h 00h 63h) - 73 - 7. Control Command Details