Craftsman 30084N Operation Manual - Page 24
Typical MIG Process Control Settings
UPC - 055249070420
View all Craftsman 30084N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 24 highlights
6-2. Typical MIG Process Control Settings NOTE These settings are guidelines only. Material and wire type, joint design, fitup, position, shielding gas, etc. affect settings. Test welds to be sure they comply to specifications. Material thickness determines weld parameters. 1/8 or .125 in .035 in Wire Size .023 in .030 in .035 in Amperage Range 30 - 90 A 40 - 145 A 50 - 180 A Wire Size .023 in .030 in .035 in Recommendation 3.5 in per ampere 2 in per ampere 1.6 in per ampere Wire Speed (Approx.) 3.5 x 125 A = 437 ipm 2 x 125 A = 250 ipm 1.6 x 125 A = 200 ipm Low voltage: wire stubs into work High voltage: arc is unstable (spatter) Set voltage midway between high/low voltage. Convert Material Thickness to Amperage (A) (.001 in = 1 ampere) .125 in = 125 A Select Wire Size Select Wire Speed (Amperage) 125 A based on 1/8 in material thickness ipm = inch per minute Select Voltage Wire speed (amperage) controls weld penetration (wire speed = burn-off rate) Voltage controls height and width of weld bead. OM-194 199 Page 21 Ref. ST-801 865