Dell External OEMR R410 Technical Guide

Dell External OEMR R410 Manual

Dell External OEMR R410 manual content summary:

  • Dell External OEMR R410 | Technical Guide - Page 1
    PowerEdge R410 Technical Guide Energy efficient and compact, the PowerEdge R410 is designed with the performance and reliability needed for High-Performance Computing.
  • Dell External OEMR R410 | Technical Guide - Page 2
    trademark and service mark of the Dell Inc. All rights reserved. Reproduction or translation of any part of this work beyond that permitted by U.S. copyright laws without the written permission of Dell Inc. is unlawful and strictly forbidden. Revision 2 October 2010 PowerEdge R410 Technical Guide
  • Dell External OEMR R410 | Technical Guide - Page 3
    1.3 Energy Efficient 7 1.4 Easy to Manage 7 1.5 Comparison to Other Dell Servers 8 2 System Overview 11 2.1 Overview 11 2.2 Product Features Summary Installation 28 6 Memory ...29 6.1 Overview 29 6.2 DIMMs Supported 29 6.3 Mirroring 29 6.4 Sparing 29 PowerEdge R410 Technical Guide iii
  • Dell External OEMR R410 | Technical Guide - Page 4
    Dell 7 Chipset ...30 7.1 Overview 30 7.2 Intel 31 7.3.4 PCI Express interface 32 8 BIOS ...33 8.1 Overview 33 8.2 Supported ACPI States 33 8.3 I2C (Inter-Integrated Circuit 34 9 Embedded NICs/LAN 53 16.2 External Storage 53 17 Packaging Options 54 PowerEdge R410 Technical Guide iv
  • Dell External OEMR R410 | Technical Guide - Page 5
    States 17 Power Supply Connector (24 pins) Signals 25 Power Supply Connector (8 pins) Signals 26 Operating/Non-Operating Storage Requirements 26 R410 Acoustical Information 27 Supported Processor Descriptions and Features 28 Wake-Up States 34 Insert I/O Slot information 36 Descriptions of
  • Dell External OEMR R410 | Technical Guide - Page 6
    Dell Figure 26. Figure 27. Figure 28. Figure 29. 1U Threaded Rack Adapter Brackets Kit 44 R410 Static Rails 44 R410 Mounted in the A3 Sliding Rails with the CMA 46 R410 Mounted in the A4 Static Rails in 2-post Center Mount Configuration 46 PowerEdge R410 Technical Guide vi
  • Dell External OEMR R410 | Technical Guide - Page 7
    space-constrained data centers and HPCC environments. The Dell PowerEdge R410 was developed with a customer-inspired design, energy are designed to make the user experience easier. We put all external ports, power supplies, LCD screens, and LED lights in the media. PowerEdge R410 Technical Guide 7
  • Dell External OEMR R410 | Technical Guide - Page 8
    as asset and security management. Dell Management Console is designed to reduce or eliminate manual processes, enabling you to save Types External Drive Bay(s) SATA/SAS/SSD 1 for slim ODD SATA/SAS/SSD 1 for slim ODD Embedded HD Controller Chipset-based SATA PowerEdge R410 Technical Guide Chipset-
  • Dell External OEMR R410 | Technical Guide - Page 9
    Dell Feature Optional Storage Controller Availability Server Mgt. I/O Slots R410 Support Only - No Factory Install) LSI2032 (For TBU) 6Gbps SAS HBA RAID: PERC6/E (Field Support Only) SAS 5/E (Field Support RAID See Optional Storage Controller PowerEdge R410 Technical Guide (embedded): PCIe x8 (x4
  • Dell External OEMR R410 | Technical Guide - Page 10
    Dell Feature NIC/LOM USB Power Supplies Fans Dimension (HxWxD) Weight R410 -hot swappable Non-redundant, non-hot- R510-12 supports swappable redundant fan 43.0 x 434.0 x 627.1 model. See the PowerEdge R510 Technical Guide for detailed information. Max: 35.02lbs (15.9Kg) Max:
  • Dell External OEMR R410 | Technical Guide - Page 11
    Dell 2 System Overview 2.1 Overview The PowerEdge R410 delivers the right combination of computing power and redundancy in an ultradense chassis. The PowerEdge R410 swap • Industry leading serviceability and diagnostics with optional -backed cache PowerEdge R410 Technical Guide PERC H800 (6Gb
  • Dell External OEMR R410 | Technical Guide - Page 12
    compliant Remote Management Optional iDRAC6 Enterprise, iDRAC6 Express Systems Management Dell™ OpenManage™ Rack Support ReadyRails™ sliding rails with optional cable management arm for 4-post Microsoft® Windows Server® 2008 SP2, x86/x64 (x64 includes Hyper-V™) PowerEdge R410 Technical Guide 12
  • Dell External OEMR R410 | Technical Guide - Page 13
    OEM Ready platforms are grab-and-go products for OEM customers delivering a fast and simple path to a custom-branded solution. For more information, please visit dell.com/OEM. PowerEdge R410 Technical Guide 13
  • Dell External OEMR R410 | Technical Guide - Page 14
    Dell 3 Mechanical 3.1 Chassis Description The PowerEdge R410 four DIMM slots support each CPU, , and support 11G slim for the PowerEdge R410 server. Table 3. R410 Overall Dimensions and dimensions of the PowerEdge R410 server. Zb goes to the nominal rear wall external surface where the motherboard
  • Dell External OEMR R410 | Technical Guide - Page 15
    Dell 3.3 Front Panel View and Features The front panel includes the following features:  Front Panel Features and Indicators section in the About Your System Chapter of the PowerEdge R410 Hardware Owner's Manual on Support.Dell.com. Figure 2. Front Without Bezel Figure 3. With Bezel View Figure 4.
  • Dell External OEMR R410 | Technical Guide - Page 16
    the back panel of the R410 server. For more information, see the BackPanel Features and Indicators in the About Your System Chapter of the PowerEdge R410 Hardware Owner's Manual. Figure 5. With Redundant that the power supply is providing DC power to the system. PowerEdge R410 Technical Guide 16
  • Dell External OEMR R410 | Technical Guide - Page 17
    Dell Amber - Indicates a problem with the power supply. Alternating green and amber - When hot- Link, activity 3.7 Side Views Side views are shown in Figure 9 and Figure 10. PowerEdge R410 Technical Guide Activity LED (Green) Off Off Off On (blinking at speed related to packet density) Off On
  • Dell External OEMR R410 | Technical Guide - Page 18
    support includes:  Toolless installation in 19‖ EIA-310-E compliant square or unthreaded round hole 4-post racks including all generations of Dell in the system and four fans with non-redundant PSU. Figure 11 shows the R410 fans. The four fans at right are the fans for the system, especially for
  • Dell External OEMR R410 | Technical Guide - Page 19
    Dell Figure 11. R410 Fans 3.10 Control Panel/LCD Figure 12 shows the front controller board with LCD. LCD module and cable/connector Internal with LCD Figure 13 shows the front controller board with the LED. Figure 13. Front Controller Board with Diagnostic LED PowerEdge R410 Technical Guide 19
  • Dell External OEMR R410 | Technical Guide - Page 20
    section in the Installing System Components chapter of the PowerEdge R410 Hardware Owner's Manual for information. 3.10.4 Trusted Platform Management (TPM) The TPM is used to generate/store keys, protect/authenticate passwords, and create/store digital certificates. TPM can also be used to store the
  • Dell External OEMR R410 | Technical Guide - Page 21
    . This mode includes the option to lock out the power and NMI switches on the control panel or set up a system password. 3.11 USB Key Dell does not offer USB keys for factory installation. 3.12 Battery Battery for the motherboard: CR2032 Figure 15. Battery Holder for PERC 6/i PowerEdge
  • Dell External OEMR R410 | Technical Guide - Page 22
    Dell Figure 16. Battery Holder for PERC PowerEdge R410 Technical Guide 22
  • Dell External OEMR R410 | Technical Guide - Page 23
    include: • Backplane • CMOS battery • Expansion card • Front bezel • HDD • I/O panel • Memory • ODD • PDB • Power supply • Processor • Processor shroud • System board • System cover • System fan PowerEdge R410 Technical Guide 23
  • Dell External OEMR R410 | Technical Guide - Page 24
    Power, Thermal, Acoustic 4.1 Power Supplies The R410 is powered by a non-redundant 480 W power supply (Dell P/N F238K) and redundant 500 W power supply (Dell P/N F649J). The power supply has automatic provided to the system via a charge pump from 3.3V standby. PowerEdge R410 Technical Guide 24
  • Dell External OEMR R410 | Technical Guide - Page 25
    Dell Figure 17. Power Supply Connector (24 pins) Table 5. Power Supply Connector (24 pins) Signals Pin Signal 1 P5V 2 P3V3 3 P12VC 4 P12VC 5 P12VE 6 GND 7 GND 19 GND 20 GND 21 GND 22 GND 23 P12VD 24 P12VD Figure 18. Power Supply Connector (8 pins) PowerEdge R410 Technical Guide 25
  • Dell External OEMR R410 | Technical Guide - Page 26
    Dell Table 6. Power Supply Connector (8 pins) Signals Pin Signal 1 GND 2 GND 3 GND 4 GND Pin Signal 5 P12VA 6 P12VA 7 P12VB 8 altitude is stated in meters and the second formula if the altitude is stated in feet. , * + - , * + - ( ) ( ) PowerEdge R410 Technical Guide 26
  • Dell External OEMR R410 | Technical Guide - Page 27
    R410 has balanced acoustic and thermal performance to support a fully-configured system and meets the Dell Acoustic specification AC0142 Rev. A02 category II-D requirement. The R410 40x56mm dual-rotor fan has an external PWM speed control, and it is 6.3 6.4 6.8 6.9 PowerEdge R410 Technical Guide 27
  • Dell External OEMR R410 | Technical Guide - Page 28
    is installed in the system, it supports 4 DIMMs, min. 1 GB and max 32 GB. When two processors are installed in the system, it supports 8 DIMMs, min. 2 GB and max 64 GB. 5.3 Processor Installation See Processors in the Hardware Owner's Manual for more information. PowerEdge R410 Technical Guide 28
  • Dell External OEMR R410 | Technical Guide - Page 29
    Dell 6 Memory 6.1 Overview Features of the PowerEdge R410 memory include: • 3 channels per processor • Support for registered ECC DDR3 DIMMs or Unbuffered ECC DDDR3 DIMMs. • DDR3 speeds of 800/1066/1333 supported (Max memory clock speed support memory installed. PowerEdge R410 Technical Guide 29
  • Dell External OEMR R410 | Technical Guide - Page 30
    supported (18 total) • Max memory of 192-GB supported • Single Rank, Dual Rank, and Quad Rank DIMMs supported • Support UDIMM and RDIMM • DDR3 speeds of 800/1066/1333 supported • 512 Mb, 1 Gb, 2 Gb, and 4 Gb Technologies/Densities supported • No memory riser support PowerEdge R410 Technical Guide
  • Dell External OEMR R410 | Technical Guide - Page 31
    Dell /sec in each direction • Hot Insertion and Removal supported with the addition of Hot-Plug control circuitry 7.2.4 6 ports. The ICH10R SATA interface supports data transfers up to 300 MB/s. UHCI host controllers to support twelve ports and two EHCI host controller to support twelve ports. An
  • Dell External OEMR R410 | Technical Guide - Page 32
    Dell 7.3.4 PCI Express interface The ICH10R has 6 PCI Express 1.1 compliant root ports. PowerEdge R410 Technical Guide 32
  • Dell External OEMR R410 | Technical Guide - Page 33
    8.1 Overview The PowerEdge R410 BIOS is based on the Dell BIOS core and supports the following features: • Intel® 5500-EP Two-Socket Support • Simultaneous Multi-Threading (SMT) support • CPU Turbo Mode support • PCI 2.3 compliant • Plug n' Play 1.0a compliant • MP (Multiprocessor) 1.4 compliant
  • Dell External OEMR R410 | Technical Guide - Page 34
    Dell Table 10. Wake-Up States Wake-Up Events RTC Power Button RI# PME# KB MOUSE USB WOL States Can Wake From OS-S4 S5 Not supported S5 Not supported Not supported Not supported This solves the many interfacing problems encountered when designing digital control . PowerEdge R410 Technical Guide 34
  • Dell External OEMR R410 | Technical Guide - Page 35
    Dell 9 Embedded NICs/LAN on Motherboard (LOM) 9.1 Overview There is Broadcom® 5716 chip on the PowerEdge R410 motherboard. The 5716 chip firmware for the LOM chip resides in a flash part. The PowerEdge R410 supports Wake-On-LAN (WOL) from either port. LOM chip: Broadcom® 5716 dual-port GbE
  • Dell External OEMR R410 | Technical Guide - Page 36
    Dell 10 I/O Slots 10.1 Overview Adapter SAS 6/iR SAS 5/iR x8 1 16 x8 2 4, 5 x4 2 4, 5 External Controllers PERC 6/E 256 PERC 6/E 512 SAS 5/E x8 2 5, 4 x8 2 5, 4 3, 4 4 2, 1, 3, 4 Intel® Gigabit VT Quad-Port Server Adapter x4 4 2, 1, 3, 4 PowerEdge R410 Technical Guide 36
  • Dell External OEMR R410 | Technical Guide - Page 37
    Dell 10.3 Boot Order PCI express lane assignments and scan order in R410: • IOH port 1, 2 (PCI Express Gen2 x4) - Broadcom BCM5716 Gigabit LOM • IOH port 3 (PCI Express Gen1 x4) - Integrated PERC6i or SAS6i - Slot 2 • IOH port 7/8/9/10 (PCI Express Gen2 x16) - Slot 1 PowerEdge R410 Technical Guide
  • Dell External OEMR R410 | Technical Guide - Page 38
    Dell 11 Storage 11.1 Overview with Description R410 supports 4 HDDS in one of the following configurations: • 4 x 3.5‖ cabled or hot-swap SAS or SATA • 4 x 2.5‖ hot-swap SAS or 21. Top-View for Hot-Swap HDD Connection Figure 22. Top-View for Cabled HDD Connection PowerEdge R410 Technical Guide 38
  • Dell External OEMR R410 | Technical Guide - Page 39
    Dell Figure 23. Cabled HDD Connectors 11.2 Drives Refer to Table 2 for supported type and capacities. 11.3 RAID Configurations Table 13. RAID Configurations Cabled/Hot /SATA - RAID1 C4 ASSR1CBL Add-in SAS/SATA RAID card, RAID 1 (SAS 6/iR or PERC 6/i) 2 2 PowerEdge R410 Technical Guide 39
  • Dell External OEMR R410 | Technical Guide - Page 40
    Dell Cabled/Hot Configuration Swap Type Configurations Description Min HDD Max HDD Cabled SAS/SATA - RAID5 C5 ASSR5CBL Add- PERC 6/i) 2xSAS + 2xSATA 2xSAS + 2xSATA 11.4 Storage Controllers Refer to Table 2 and Section 10.2 for detailed information. PowerEdge R410 Technical Guide 40
  • Dell External OEMR R410 | Technical Guide - Page 41
    Dell 11.5 LED Indicators LED indicator for R410 supports a SATA interface DVD-ROM or DVD+/-RW. Refer to Table 2. 11.7 Tape Drives R410 does not support an internal backup device. Only external backup device is supported. Refer to Table 2 for the supported devices. PowerEdge R410 Technical Guide
  • Dell External OEMR R410 | Technical Guide - Page 42
    Dell 12 Video Matrox® G200eW with 8 MB memory integrated in Winbond WPCM450 (Baseboard Management Controller). • 1280x1024 at o 1280x1024 (60/75/85 Hz; 8/16-bit color) o 1280x1024 (60 Hz, 32-bit color) (32 bit color is only supported at 60 Hz for this resolution) PowerEdge R410 Technical Guide 42
  • Dell External OEMR R410 | Technical Guide - Page 43
    R410 provide toolless support for 4-post racks with square or unthreaded round mounting holes including all generations of Dell racks. Both support service and are available with or without the optional cable management arm (CMA). Figure 25. R410 A detailed Getting Started Guide is included in the
  • Dell External OEMR R410 | Technical Guide - Page 44
    Figure 26. 1U Threaded Rack Adapter Brackets Kit The static rails support a wider variety of racks than the sliding rails but do not support serviceability in the rack and are thus not compatible with the CMA. Figure 27. R410 Static Rails One key factor in selecting the proper rails is identifying
  • Dell External OEMR R410 | Technical Guide - Page 45
    Supported 4-Post 2-Post Square Round Thread Flush Center A3 ReadyRails™ Sliding √ √ √* X X A4 ReadyRails/Generic Static √ √ √ √ √ *Requires the 1U Threaded Rack Adapter Brackets Kit (Dell support and retain the CMA in its fully closed position PowerEdge R410 Technical Guide 45
  • Dell External OEMR R410 | Technical Guide - Page 46
    Dell  Both the CMA and the tray mount without the use of tools via simple and intuitive snap-in designs 13.4 Rack View The R410 service or replacement. Figure 28. R410 Mounted in the A3 Sliding Rails with the CMA The R410 R410 Mounted in the A4 Static Rails in 2-post Center Mount Configuration
  • Dell External OEMR R410 | Technical Guide - Page 47
    Dell 14 Operating Systems and Virtualization For detailed information, see the Operating System Support Matrix for Dell PowerEdge Systems on Dell.com. PowerEdge R410 Technical Guide 47
  • Dell External OEMR R410 | Technical Guide - Page 48
    These tools are Remote Access Service, for iDRAC, and Dell Management Console DVDs, customers have the option to obtain Server Update Utility DVD. This DVD has an inventory tool for managing updates to firmware, BIOS and drivers for either Linux or Windows varieties. PowerEdge R410 Technical Guide
  • Dell External OEMR R410 | Technical Guide - Page 49
    utility are embedded on system, so no need to scour DELL.COM Faster System Updates Integration with Dell support automatically directed to latest versions of the Unified Server Configurator, utility. Also provides configuration for iDRAC, BIOS, and NIC/LOM. PowerEdge R410 Technical Guide 49
  • Dell External OEMR R410 | Technical Guide - Page 50
    Dell states • Advanced troubleshooting capabilities For connects directly to the R410 planar and is mounted include: • Scripting capability with Dell's Racadm command-line • Remote card. This is a 1 GB Dell branded SD card that enables a Feature BMC Interface and Standards Support IPMI 2.0  Web-
  • Dell External OEMR R410 | Technical Guide - Page 51
    Dell Feature BMC IPv4  VLAN Tagging  IPv6 Dynamic DNS  Power  Counters* Logging Features System Event Log  PowerEdge R410 Technical Guide iDRAC6 Express iDRAC6 Enterprise                                
  • Dell External OEMR R410 | Technical Guide - Page 52
    Dell Feature RAC Log Trace Log BMC iDRAC6 Express iDRAC6 Enterprise vFlash Media      PowerEdge R410 Technical Guide 52
  • Dell External OEMR R410 | Technical Guide - Page 53
    Dell 16 Peripherals 16.1 USB Peripherals Optional USB 1.44 MB floppy drive Optional USB DVD-ROM 16.2 External Storage Refer to Table 2. PowerEdge R410 Technical Guide 53
  • Dell External OEMR R410 | Technical Guide - Page 54
    Dell 17 Packaging Options • Options for single pack and multipack are available. • Multipack will support four units in one pack. • Single Pack Dimensions and Weights: o Inside Dimensions: out weight: 58 lbs  Cushion weight: 2 lbs  Corrugated box weight: 8.5 lbs PowerEdge R410 Technical Guide 54
  • Dell External OEMR R410 | Technical Guide - Page 55
    Dell Appendix A. R410 Volatility Chart The Dell PowerEdge R410 contains both volatile and non-volatile (NV) components. Volatile components lose their data immediately upon ? N/A Remarks Jumper on motherboard can be used to clear to factory default settings PowerEdge R410 Technical Guide 55
  • Dell External OEMR R410 | Technical Guide - Page 56
    Dell LOM (LAN [Network Interface] on Motherboard) Memory Size: Type: [e.g., Flash PROM, EEPROM]: Can user programs or operating system write Details 256 Bytes SEEPROM No Store power supply information Programmed by the power supply manufacturer. Not write protected PowerEdge R410 Technical Guide 56
  • Dell External OEMR R410 | Technical Guide - Page 57
    Dell TPM (Trusted Platform Module for boards shipped outside of China; Boards sold to destinations in China do not have TPM at this time) not operate. Details 1 GB SD card Yes Optional embedded boot device Factory installed or via USB bus. Not write protected PowerEdge R410 Technical Guide 57
  • Dell External OEMR R410 | Technical Guide - Page 58
    arbitrary data in firmware memory would not operate. Software write protected To obtain optional component information, please refer to the Dell Statement of Volatility for the individual components. Please direct any questions to your Dell Marketing contact. PowerEdge R410 Technical Guide 58
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58

PowerEdge R410
Technical Guide
Energy efficient and
compact, the
PowerEdge R410 is
designed with the
performance and
reliability needed for
High-Performance
Computing
.