EVGA 132-CK-NF78-TR User Manual - Page 63

Expert, Command Per Clock

Page 63 highlights

780i 3-Way SLI Motherboard ¾ Expert Use the Page Up and Page Down keys to select Expert. When Expert is selected, all timing categories are enabled for manual input. Note that you should set the value to Optimal to use the manufacturers' recommended values. Parameters Settings Current Value Memory Timing Setting tCL (CAS Latency) tRDC tRP tRAS Command Per Clock (CDM) [Expert] [Auto(5)] [Auto(7)] [Auto(7)] [Auto(23)] [Auto(2T)] ** Advanced Memory Settings ** tRRD [Auto(4)] tRC [Auto(28)] tWR [Auto(7)] tWTR [Auto(10)] tREF [Auto] 5 5 5 18 1T 3 22 5 9 6.1uS Š tCL: CAS# latency (options are 1 through 6). Š tRDC: RAS#-to-CAS# Delay for Read/Write commands to the same bank (options are 1 through 7). Š tRP: Row Precharge time. This is the Precharge-to-Active or Auto- to-Refresh of the same bank (options are 1 through 7). Š tRAS: This is the minimum RAS# active time (options are 1 through 31). Š Command Per Clock: This is the command timing setting on a per clock unit basis (options are 1T and 2T). Š tRRD: RAS#-to-RAS# delay of different banks (options are 1 through 15). Š tRC: RAS#-to-RAS# or auto refresh time of the same bank (options are 1 through 31). Š tWR: The Write recovery time (options are 2 through 7). Š tWTR: This is the minimum write-to-read delay with the same chip selected (options are 1 through 10). EVGA 52

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127

780i 3-Way SLI Motherboard
EVGA
52
Expert
Use the
Page Up
and
Page Down
keys to select
Expert
. When Expert is
selected, all timing categories are enabled for manual input. Note that you
should set the value to Optimal to use the manufacturers’ recommended
values.
tCL
:
CAS# latency (options are 1 through 6).
tRDC
:
RAS#-to-CAS# Delay for Read/Write commands to the
same bank (options are 1 through 7).
tRP
:
Row Precharge time. This is the Precharge-to-Active or Auto-
to-Refresh of the same bank (options are 1 through 7).
tRAS
: This is the minimum RAS# active time (options are 1 through
31).
Command Per Clock
: This is the command timing setting on a per
clock unit basis (options are 1T and 2T).
tRRD
: RAS#-to-RAS# delay of different banks (options are 1
through 15).
tRC
:
RAS#-to-RAS# or auto refresh time of the same bank (options
are 1 through 31).
tWR
:
The Write recovery time (options are 2 through 7).
tWTR
:
This is the minimum write-to-read delay with the same chip
selected (options are 1 through 10).
Parameters
Settings Current Value
Memory Timing Setting
[
Expert
]
tCL (CAS Latency)
[Auto(5)]
5
tRDC
[Auto(7)]
5
tRP
[Auto(7)]
5
tRAS
[Auto(23)]
18
Command Per Clock (CDM)
[Auto(2T)]
1T
** Advanced Memory Settings **
tRRD
[Auto(4)]
3
tRC
[Auto(28)]
22
tWR
[Auto(7)]
5
tWTR
[Auto(10)]
9
tREF
[Auto]
6.1uS