EVGA 132-YW-E178-A1 User Guide - Page 67

Command Per Clock

Page 67 highlights

Parameters Settings Current Value Memory Timing Setting tCL (CAS Latency) tRDC tRP tRAS Command Per Clock (CDM) [Expert] [Auto(5)] [Auto(7)] [Auto(7)] [Auto(23)] [Auto(2T)] ** Advanced Memory Settings ** tRRD [Auto(4)] tRC [Auto(28)] tWR [Auto(7)] tWTR [Auto(10)] tREF [Auto] 5 5 5 18 1T 3 22 5 9 6.1uS tCL: CAS# latency (options are 1 through 6). tRDC: RAS#-to-CAS# Delay for Read/Write commands to the same bank (options are 1 through 7). tRP: Row Precharge time. This is the Precharge-to-Active or Auto-to-Refresh of the same bank (options are 1 through 7). tRAS: This is the minimum RAS# active time (options are 1 through 31). Command Per Clock: This is the command timing setting on a per clock unit basis (options are 1T and 2T). tRRD: RAS#-to-RAS# delay of different banks (options are 1 through 15). tRC: RAS#-to-RAS# or auto refresh time of the same bank (options are 1 through 31). tWR: The Write recovery time (options are 2 through 7). tWTR: This is the minimum write-to-read delay with the same chip selected (options are 1 through 10). tREF: This is the DRAM refresh rate (options are Auto, 7.8uS, and 3.9uS). EVGA 56

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85

EVGA
56
tCL
:
CAS# latency (options are 1 through 6).
tRDC
:
RAS#-to-CAS# Delay for Read/Write commands to the same bank (options
are 1 through 7).
tRP
:
Row Precharge time. This is the Precharge-to-Active or Auto-to-Refresh of the
same bank (options are 1 through 7).
tRAS
: This is the minimum RAS# active time (options are 1 through 31).
Command Per Clock
: This is the command timing setting on a per clock unit basis
(options are 1T and 2T).
tRRD
: RAS#-to-RAS# delay of different banks (options are 1 through 15).
tRC
:
RAS#-to-RAS# or auto refresh time of the same bank (options are 1 through
31).
tWR
:
The Write recovery time (options are 2 through 7).
tWTR
:
This is the minimum write-to-read delay with the same chip selected (options
are 1 through 10).
tREF
: This is the DRAM refresh rate (options are
Auto
,
7.8uS
, and
3.9uS
).
Parameters
Settings Current Value
Memory Timing Setting
[
Expert
]
tCL (CAS Latency)
[Auto(5)]
5
tRDC
[Auto(7)]
5
tRP
[Auto(7)]
5
tRAS
[Auto(23)]
18
Command Per Clock (CDM)
[Auto(2T)]
1T
** Advanced Memory Settings **
tRRD
[Auto(4)]
3
tRC
[Auto(28)]
22
tWR
[Auto(7)]
5
tWTR
[Auto(10)]
9
tREF
[Auto]
6.1uS