Installation Instructions Electrical Connections cont. 3 POWER CORD AND STRAIN RELIEF INSTALLATION A Remove the wire cover (on the back of the range) by removing 2 screws, using a 1/4″ nut driver. Do not discard these Wire Cover screws. B Remove the knockout ring (1-3/8″) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed. Terminal block (appearance may vary) C For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit. NOTE: Do not install the power cord without a strain relief. The strain relief bracket should be installed before reinstalling the rear range wiring cover. Terminal block Strain relief Power cord Bracket Knockout ring in bracket Knockout ring removed D For conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block. NOTE: Do not install the conduit without a squeeze connector. The squeeze connector should be installed before reinstalling the rear range wiring cover. Terminal block Squeeze connector Conduit Bracket 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

8
Installation Instructions
Electrical Connections
cont.
3
POWER CORD AND STRAIN
RELIEF INSTALLATION
A
Remove the wire cover
(on the back of the
range) by removing 2
screws, using a 1/4
nut driver.
Do not discard these
screws.
Wire
Cover
B
Remove the knockout ring (1-3/8
)
located on bracket directly below the
terminal block. To remove the knockout,
use a pair of pliers to bend the knockout
ring away from the bracket and twist
until ring is removed.
Terminal block
(appearance
may vary)
Knockout
ring removed
Knockout ring
in bracket
C
For power cord installations only
(see
the next step if using conduit), assemble
the strain relief in the hole. Insert the
power cord through the strain relief and
tighten. Allow enough slack to easily
attach the cord terminals to the terminal
block. If tabs are present at the end of
the winged strain relief, they can be
removed for better fit.
NOTE: Do not install the power cord
without a strain relief. The strain relief
bracket should be installed before
reinstalling the rear range wiring
cover.
Terminal
block
Strain relief
Power cord
Bracket
D
For conduit installations only,
purchase a squeeze connector matching
the diameter of your conduit and
assemble it in the hole. Insert the conduit
through the squeeze connector and
tighten. Allow enough slack to easily
attach the wires to the terminal block.
NOTE:
Do not install the conduit without
a squeeze connector. The squeeze
connector should be installed before
reinstalling the rear range wiring cover.
Terminal
block
Squeeze
connector
Conduit