Hayward TriStar XL HCP3000 Series Variable Speed Pump - Owners Manual - Page 22

Maintenance

Page 22 highlights

3. Quick Clean press Resume to end NOTE: The above message will be displayed while Quick Clean is running. Quick Clean mode runs at the Max allowed speed and expires after 60 min, and it may be cancelled early by pressing the Stop/Resume button, at which time the pump would return to normal operation. Quick Clean can be extended up to 360 minutes with additional presses of the Quick Clean button. Remote Stop Screen 1. Remote Stop is engaged NOTE: The above message will be displayed when an installed remote stop switch is activated. The pump will remain stopped until the remote stop switch is deactivated. See page 13 for more detail. Maintenance • Clean strainer basket regularly. Do NOT strike basket. Inspect cover gasket regularly and replace as necessary. • Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary. • Keep motor clean. Keep motor air vents free of obstructions to avoid damage. Do NOT use water to hose off motor. • Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See "Shaft Seal Change Instructions" in this manual. Storage/Winterization ! WARNING - Separation Hazard. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter, or piping. ! ATTENTION - Allowing the pump to freeze with water in it will void the warranty. ! ATTENTION - Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene glycol is nontoxic and will not damage plastic system components; other anti-freezes are highly toxic and may damage plastic components in the system. Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Gravity drain system as far as possible. Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump with plastic film or bags. Storing Pump for Winterization ! WARNING - To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. Failure to disconnect power may result in serious personal injury or death. 1. Drain water level below all inlets to the pool. 2. Remove drain plugs and strainer cover from strainer housing (see parts diagram on page 23 for pump component locations). 3. Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping. 4. Once the pump is fully drained of water, re-install the strainer cover and drain plugs. Store pump in a dry area. 21 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
21
3.
NOTE: The above message will be displayed while Quick Clean is running. Quick Clean mode runs at the Max allowed speed and expires after 60 min, and it
may be cancelled early by pressing the Stop/Resume button, at which time the pump would return to normal operation. Quick Clean can be extended up to 360
minutes with additional presses of the Quick Clean button.
Remote Stop
1.
NOTE: The above message will be displayed when an installed remote stop switch is activated. The pump will remain stopped until the remote stop switch is
deactivated. See page 13 for more detail.
Maintenance
Clean strainer basket regularly. Do NOT strike basket. Inspect cover gasket regularly and replace as necessary.
Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
Keep motor clean. Keep motor air vents free of obstructions to avoid damage. Do NOT use water to hose off motor.
Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See “Shaft Seal Change Instructions”
in this manual.
Storage/Winterization
WARNING
Separation Hazard.
Do not purge the system with compressed air. Purging the system with compressed air can cause components to
explode, with risk of severe injury or death to anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, filter,
or piping.
ATTENTION
– Allowing the pump to freeze with water in it will void the warranty.
ATTENTION
– Use ONLY propylene glycol as antifreeze in your pool/spa system. Propylene glycol is nontoxic and will not damage plastic system
components; other anti-freezes are highly toxic and may damage plastic components in the system.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions below). Gravity drain system
as far as possible.
Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump with plastic film or bags.
Storing Pump for Winterization
WARNING
– To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor before draining pump. Failure to disconnect power may
result in serious personal injury or death.
1.
Drain water level below all inlets to the pool.
2.
Remove drain plugs and strainer cover from strainer housing (see parts diagram on page 23 for pump component locations).
3.
Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping.
4.
Once the pump is fully drained of water, re-install the strainer cover and drain plugs. Store pump in a dry area.
!
!
!
!
Screen
Remote Stop
is engaged
Quick Clean
press Resume to end