HP StorageWorks 2012fc Modular Smart Array user guide Part number: 481597-001 First edition: March, 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 2
express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft and Windows are U.S. registered trademarks of Microsoft - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 3
7 Document Conventions 8 Rack Stability 8 HP Technical Support 9 Customer Self Repair 9 Product Warranties 9 Subscription Service 10 HP Websites 10 Documentation Feedback 10 1. Before You Begin 11 System Management Software 12 HP StorageWorks MSA2000 Family Storage Management Utility (SMU - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 4
Caps 31 Connecting Controller and Drive Enclosures 32 Connecting AC Power 35 Testing the Enclosure Connections 36 Obtaining IP Values for Your Storage System 36 Correcting Connecting Remote Management Hosts 48 Next Steps 48 4 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 5
Port IP Addresses Using the CLI 50 Configuring Your Web Browser for SMU 53 Logging in to SMU from a Local Management Host 54 Updating Firmware 54 Setting the Date and Time 54 Configuring Host Ports 55 Creating Virtual Disks 57 Mapping a Data Host to a Volume 58 Testing the Configuration - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 6
6 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 7
) management ■ Network administration ■ Network installation ■ Storage system installation and configuration, including installing an HP rack Prerequisites Prerequisites for installing and configuring this product include familiarity with: ■ Servers and computer networks ■ Fibre Channel and Ethernet - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 8
screen output AaBbCc123 Variable text you replace with an actual value Examples See the Release Notes. A virtual disk (vdisk) can .... You must be an advanced user to .... The default file name is store.logs. The default extended. 8 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 9
(CSR) programs allow you to repair your HP StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HPauthorized service provider will determine whether a repair can be accomplished - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 10
://www.hp.com/support/downloads Documentation Feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 11
The MSA2000 Family 2012fc Modular Smart Array and MSA2000 Drive Enclosure are high-performance storage solutions that combine outstanding performance with high reliability, availability, flexibility, and manageability. Supported configurations include a controller enclosure with or without attached - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 12
below. HP StorageWorks MSA2000 Family Storage Management Utility (SMU) SMU is the primary interface for configuring and managing the system. A web server resides in each controller module. the CLI is in the CLI reference guide. 12 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 13
enclosure AC power-and-cooling module 2 per enclosure 2- or 4-Gbps FC host port with SFP 2 per controller module 3-Gbps, 4-lane SAS expansion port 1 per controller module Ethernet port (RJ-45) 1 per controller module CLI port (RS-232 micro-DB9) 1 per controller module Service port (RS-232 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 14
controller Service action is required. The event has been acknowledged but the problem needs attention. The enclosure is powered on with at least one power and cooling module operating normally. Both power and cooling modules are off. 14 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 15
Table 1-3 describes the LEDs on the drive module. Table 1-3 Drive Module LED Combinations (Front) Online/Activity (green) On Blinking irregularly Off Fault/UID (amber/blue) Off Off Amber, blinking regularly (1 Hz) On Amber, blinking regularly (1 Hz) Blinking irregularly Off Amber, blinking - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 16
port used to connect the controller enclosure to a local management host using RS-232 communication for out-of-band configuration and management. Controller Service port 3.5-mm jack port used by service technicians only. module 16 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 17
the LEDs on the back of the controller. Table 1-5 Controller LEDs (Back) Location LED Power and AC Power Good cooling module Power and DC Voltage/ cooling Fan Fault/ module Service Required Controller Host link status module Controller Host link speed module Color Green State Description - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 18
Green Off The Ethernet link has no I/O activity. Blink The Ethernet link has I/O activity. Controller Expansion port module status Green Off The port is empty or the link is down. On The port link is up and connected. 18 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 19
be connected to a controller enclosure or to another drive enclosure to provide additional disk storage capacity. Table 1-6 AC power and cooling module 2 per enclosure 3-Gbps, 4-lane SAS In port 1 per expansion module 3-Gbps, 4-lane SAS Out port 1 per expansion module Service port (RS-232 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 20
ingress port used to connect to a controller enclosure. SAS Out port 3-Gbps, 4-lane (12 Gbps total) table-routed egress port used to connect to another drive enclosure. Service port Micro-DB9 port for manufacturing technicians. 20 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 21
back of the drive enclosure. Table 1-8 Drive Enclosure LEDs (Back) Location LED Power and AC Power Good cooling module Power and DC Voltage/ cooling Fan Fault/ module Service Required Expansion SAS In port status module Expansion module Unit Locator Expansion module OK to Remove Color Green - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 22
-controlled power up or a cache flush or restore error. Off Expansion module is not OK. On Expansion module is operating normally. Blink System is booting. Off The port is empty or the link is down. On The port link is up and connected. 22 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 23
7. Obtain IP values. "Obtaining IP Values for Your Storage System" on page 36 8. Install required host software and controller enclosure • Verify that controllers and enclosures have the latest firmware • Set the date and time on the controller enclosure • Configure host ports on the controller - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 24
24 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 25
Rack" on page 27 ■ "Attaching the Ear Caps" on page 31 ■ "Connecting Controller and Drive Enclosures" on page 32 ■ "Connecting AC Power" on page 35 ■ "Testing the Enclosure Connections" on page 36 ■ "Obtaining IP Values for Your Storage System" on page 36 ■ "Correcting Enclosure IDs" on page 37 ■ " - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 26
following safety precautions when setting up your equipment: ■ Follow all cautions and instructions marked on the equipment. ■ Ensure that the voltage and frequency of before touching a static-sensitive component or assembly. 26 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 27
a rack cabinet, ensure the rack is installed according to its installation instructions and that the installation complies with local safety codes. 1. Stabilize the the rack from rolling. 3. Remove or open the top front panel and the vented back panel. Chapter 2 Installing and Cabling Enclosures 27 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 28
Threaded PEMs (4) Side bracket #8-32 x 3/16-in. flathead screws (Step 5) #8-32 x 1/4-in. flathead screws (Step 8) Figure 2-1 Overview of Standard 19-Inch EIA Rackmounting Components 28 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 29
nylon front support brackets. If possible, position the enclosure on top of another device or shelf in the rack to hold the enclosure as you attach the front brackets. 1. Considering your system configuration and weight distribution in the rack, determine where you will install each enclosure - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 30
the optional front support nylon brackets to the rack face, remove those brackets. Note - When you finish installing an enclosure, you may have unused screws left in your rack kit; extra screws are provided in case any are misplaced. 30 HP StorageWorks 2012fc Modular Smart Array user guide • March - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 31
removing them. After the enclosure has been installed in the rack cabinet, attach the ear caps, which are located in a plastic bag included in the controller enclosure package. 1. Remove the ear caps from the plastic package. 2. As you attach each ear cap, hold it so that its indent is closest to - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 32
illustrations showing all components, see "Hardware Components and LEDs" on page 13. Controller A Controller B In Out 1A In Out 1B Figure 2-4 Cabling Connections Between One Controller Enclosure and One Drive Enclosure 32 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 33
Controller A Controller B In Out 1A In Out 1B In Out 2A In Out 2B In Out 3A In Out 3B Figure 2-5 Fault-Tolerant Cabling Connections Between One Controller Enclosure and Up to Three Drive Enclosures Chapter 2 Installing and Cabling Enclosures 33 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 34
Controller A Controller B In Out 1A In Out 1B In Out 2A In Out 2B 3A In Out 3B In Out Figure 2-6 Non-Fault-Tolerant Cabling Connections Between One Controller and Up to Three Drive Enclosures 34 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 35
Verify that both power switches are off. 2. Using the AC power cords, for each enclosure, connect one power and cooling module to one power source in the rack, and the other power and cooling module to a separate power source in the rack. 3. Connect the primary power cords from the rack to separate - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 36
the back of the controller enclosure to the will need to obtain the IP addresses from your network administrator, and set them using the CLI during initial configuration (see "Setting Management Port IP Addresses Using the CLI" on page 50). 36 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 37
both controllers are up and perform a rescan using SMU or the CLI. This will reorder the enclosures, but can take up to two minutes for the enclosure IDs to be corrected. To perform a rescan using the CLI, type the following command: rescan To rescan using SMU, as an Advanced Manage user - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 38
38 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 39
Modular Smart Arrays must meet the following requirements: ■ To configure an FC HBA that is directly attached to controller enclosure host ports, set the HBA parameters as specified in the MSA QuickSpecs. QuickSpecs can be found from your HP MSA products page at http://www.hp.com/go/msa. Select MSA - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 40
Switch attach storage places one or more FC switches between the controller enclosure and data hosts. This enables more than one host to share a storage system and provides a level of redundancy if more than one switch is used. 40 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 41
only. Use this default setting when controller enclosures are attached through one or more switches, or when they are attached directly but performance is more important than availability. Using Loop or Point-to-Point Topology MSA2000 Family 2012fc Modular Smart Arrays use Fibre Channel Arbitrated - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 42
all components, see "Hardware Components and LEDs" on page 13. Figure 3-1 shows a single-controller to a single-port data host configuration. Figure 3-1 Single-Controller, Direct Attach Connection to One Single-Port Data Host 42 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 43
requires that host port interconnects are enabled as described in "Configuring Host Ports" on page 55. Interconnect enabled through SMU Controller A Controller B Figure 3-3 High-Availability, Dual-Controller, Direct Attach Connection to Two Dual-Port Data Hosts Chapter 3 Connecting Hosts 43 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 44
requires host port interconnects to be disabled, which they are by default. Controller A Controller B Figure 3-4 High-Performance, Dual-Controller, Direct Attach Connection to Two Dual-Port Data Hosts (Not Fault Tolerant) 44 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 45
controller enclosure to data hosts through one or more external FC switches. The controller enclosure has four host connections, two per controller. Connect FC cables from controller the controller host ports to which they are connected. A speed mismatch prevents the host from accessing the storage - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 46
host port interconnects are disabled, which they are by default. It also requires host-based multipathing software. Controller A Controller B Figure 3-5 Dual-Controller Connection Through One Switch to One Dual-Port Data Host 46 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 47
, in which each data host has two FC HBA ports with each port connected to a different switch. This configuration requires that host port interconnects are disabled, which they are by default. Switch A Switch B Controller A Controller B Figure 3-6 High-Availability Connection Through Two Switches - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 48
management host. 1. Connect an Ethernet cable to the Ethernet management port on each controller. 2. Connect the other end of each Ethernet cable to a network that configuration on the storage system as described in Chapter 4. 48 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 49
on the storage system. It also describes how to perform basic storage configuration to ■ "Logging in to SMU from a Local Management Host" on page 54 ■ "Updating Firmware" on page 54 ■ "Setting the Date and Time" on page 54 ■ "Configuring user's password, refer to SMU's online help or the reference - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 50
storage system. 1. From your network administrator obtain an IP address, subnet mask, and gateway address for controller A and controller B. 2. Use the provided micro-DB9 serial cable to connect controller A to a serial port on a host computer. 50 HP StorageWorks 2012fc Modular Smart Array user - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 51
serial cable to a DB25 serial port on the host computer. 3. Start and configure a terminal emulator, such as support) Font Terminal Translations None Columns 80 Table 4-2 Terminal Emulator Connection Settings Parameter Connector Baud rate (bits/sec) Data bits Parity Stop bits Flow control - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 52
command to verify the new IP addresses: show network-parameters Network parameters, including the IP address, subnet mask, and gateway address are displayed for each controller. 8. Disconnect from the CLI and exit the emulator. 52 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 53
the host computer's command window, type the following command to verify Ethernet connectivity, first for controller A and then for controller B: ping SMU uses popup windows to indicate the progress of user-requested tasks, disable any browser features or tools that block popup windows. ■ For - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 54
If you want to synchronize the times and logs between storage devices installed in multiple time zones, set all the storage devices to use UT. ■ If you want to use the local time for the device, set its time zone appropriately. 54 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 55
from the NTP server. Configuring Host Ports Note - If you need to change FC Loop ID settings as described below, consult with your network administrator on the best addresses to use. To configure controller enclosure host ports: 1. Select Manage > General Config > Host Port Configuration. Chapter - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 56
Controller Module Host Port Configuration panels, select Point to Point for each port, and click Save and Continue. Note - If interconnects are enabled, you cannot use point-to-point topology. The Host Port Configuration page displays again. 56 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 57
storage capacity can then be partitioned into volumes. SMU provides both manual and automatic methods for creating virtual disks, as described in its online help and in the reference guide number of volumes, select 1. Notice that by default the volume will not be exposed to (accessible by) hosts. 10 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 58
panel: a. Select the host port WWN value that you identified before beginning. b. Type the LUN that you identified. Notice that the mapped host will have read-write access through all controller host ports. c. Click Map It. 58 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 59
manage users cannot log in to the same controller module and your IP address stays logged in for 30 minutes (the default auto-logout covered in this guide. For additional information on configuring your system and performing administrative tasks, refer to SMU's online help or the reference guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 60
60 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 61
enclosure. This ensures that the disks in the drive enclosures have enough time to completely spin up before being scanned by the RAID controllers in the controller enclosure. Depending on your configuration, it can take several minutes for the system to power up. Use this procedure to turn power on - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 62
2. Press the power switches at the back of the controller enclosure to the On (-) position. If the enclosure's power-on sequence succeeds as described in Step 1, the system is ready to use. 62 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 63
expected to be installed in a residential environment (i.e., personal computers). The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 64
, in which case the user will be required to hp.com. For questions regarding this FCC declaration, contact us by mail or telephone: ■ Hewlett-Packard Company P.O. Box 692000, Mailstop 510101 Houston, Texas 77269-2000 ■ 1-281-514-3333 64 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 65
this device that are not expressly approved by Hewlett-Packard Company may void the user's authority to operate the equipment. Cables Connections to this device must be the 2012fc Modular Smart Array is located behind the left ear on the side of the chassis. Laser Device All HP systems equipped - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 66
of the HP supplied laser device. This optional label indicates that the product is classified as a CLASS 1 LASER PRODUCT. This label may appear on the laser device installed in your product. Figure 4-1 Class 1 Laser Product Label 66 HP StorageWorks 2012fc Modular Smart Array user guide • March - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 67
International Notices and Statements Canadian Notice (avis Canadien) Class A Equipment This Class A digital apparatus meets all requirements of the Canadian InterferenceCausing Equipment Regulations. Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 68
■ Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information Technology Equipment. BSMI Notice Japanese Notice 68 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 69
to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized reseller or HP authorized service provider. Warning - Your computer contains an internal lithium manganese - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 70
service provider. Note - Route power cords so that they will not be walked on and cannot be pinched by items placed upon or against them. Pay particular attention to the plug, electrical outlet, and the point where the cords exit from the product. 70 HP StorageWorks 2012fc Modular Smart Array user - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 71
wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm floors or dissipating floor mats. ■ Use conductive field service tools. ■ Use a portable field service kit with a folding static-dissipating work mat. If - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 72
on static electricity, or assistance with product installation, contact your HP authorized reseller. Waste Electrical and Electronic Equipment Directive Czechoslovakian Notice eller i den butik, hvor du købte produktet. 72 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 73
recycling. English Notice Disposal of waste equipment by users in private household in the European Union This of your waste equipment at the time of disposal will help to conserve natural resources and ensure that your household waste disposal service, or the shop where you purchased the product - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 74
ja suojelee luontoa. Lisätietoja paikoista, joihin hävitettävät laitteet voi toimittaa kierrätettäväksi, saa ottamalla yhteyttä jätehuoltoon tai liikkeeseen, josta tuote on ostettu. 74 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 75
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, l es services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German Notice Entsorgung von Altgeräten aus privaten - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 76
és pontos helyér l b vebb tájékoztatást a lakhelye szerint illetékes önkormányzattól, az illetékes szemételtakarító vállalattól, illetve a terméket elárusító helyen kaphat. 76 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 77
Italian Notice Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le apparecchiature - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 78
mo na przekaza zu yty sprz t do recyklingu, nale y si skontaktowa z urz dem miasta, zakładem gospodarki odpadami lub sklepem, w którym zakupiono produkt. 78 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 79
e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian Notice Appendix B Regulatory Compliance and Safety - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 80
los puntos de recogida de residuos eléctricos y electrónicos para reciclado, póngase en contacto con su ayuntamiento, con el servicio de eliminación de residuos domésticos o con el establecimiento en el que adquirió el producto. 80 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 81
Swedish Notice Bortskaffande av avfallsprodukter från användare i privathushåll inom Europeiska Unionen Om den här symbolen visas på produkten eller förpackningen betyder det att produkten inte får slängas på samma ställe som hushållssopor. I stället är det ditt ansvar att bortskaffa avfallet genom - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 82
82 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 83
, regulatory compliance notice, 67 B batteries recycling or disposal, 70 replacement notice, 69 Taiwan EPA recycling and disposal, 70 boot straps, hosts, 48 controller modules LEDs cache status, 18 Ethernet activity, 18 Ethernet link status, 18 expansion port status, 18 Fault/Service Required, 18 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 84
port interconnects, 55 setting FC loop IDs, 55 setting FC topology, 55 hosts, See data hosts HP address for FCC questions, 64 series number, 65 telephone number FCC questions, 64 HyperTerminal settings, See terminal emulator 84 HP StorageWorks 2012fc Modular Smart Array user guide • March 2008 - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 85
, 18, 21 lithium battery, 69 loop topology, 41 M managing storage systems using SMU, 12 using the CLI, 12 mapping, data hosts cooling modules LEDs AC Power Good, 17, 21 DC Voltage/Fan Fault/Service Required, 17, 21 power switches, 16, 20 power cord compliance notice, 70 current rating, 70 replacement - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 86
, 65 modifications, 65 shielded cables, 65 remote management, 48 replacing a power cord, 70 reverse cabling, 32 RFI/EMI connector HP storage, 10 HP Subscriber's choice, 10 work mat, static-dissipating, 71 wrist straps specifications, 71 86 HP StorageWorks 2012fc Modular Smart Array user guide - HP 2000fc | HP StorageWorks 2012fc Modular Smart Array user guide (481597-001, M - Page 87