HP 2000sa HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911- - Page 104

down disk., health and status FTDN fault tolerant with

Page 104 highlights

Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 322 Warning The controller has an older SC version than the version used to create the CHAP authentication database in the controller's flash memory. The CHAP database cannot be read or updated. However, new records can be added, which will replace the existing database with a new database using the latest known version number. Upgrade to an SC version that is current for the indicated database version. • If no records were added, the database becomes accessible and remains intact. • If records were added, the database becomes accessible but contains only the new records. 352 Informational EC assert data or stack-dump data is accessible. 353 Informational EC assert data and stack-dump data have been cleared. 354 Informational SAS topology has changed on a host port. or warning For example, the SAS cable connecting a controller host port to a host has been disconnected. This event is logged as informational for a topology change where at least one PHY goes "up." This event is logged as a warning for a topology change where at least one PHY goes "down." 355 Warning The faceplate's debug button was found to be stuck in the On position during boot up. 412 Warning One disk in the specified RAID-6 vdisk failed. The vdisk is operational with Degraded health and status FTDN (fault tolerant with a down disk). Replace the down disk with a spare so the system can start reconstructing the vdisk. 443 Warning A firmware version mismatch has been detected in an MSA70 drive enclosure. The enclosure should be updated to the latest supported version of firmware as soon as possible. In the drive enclosure all FRUs (I/O module, fan, power supply, midplane, backplane, and 7-segment LED) must be at a combined proper firmware recipe. The two I/O modules must be at equal firmware versions. Any replaced MSA70 FRUs might have older firmware that does not match an internally defined recipe. Update the drive enclosure to the latest firmware version to ensure all FRUs are at the proper firmware level. 104 Event code reference

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

104
Event code reference
322
Warning
The controller has an older SC version than
the version used to create the CHAP
authentication database in the controller’s
flash memory.
The CHAP database cannot be read or
updated. However, new records can be
added, which will replace the existing
database with a new database using the
latest known version number.
Upgrade to an SC version that is current for
the indicated database version.
If no records were added, the database
becomes accessible and remains intact.
If records were added, the database
becomes accessible but contains only
the new records.
352
Informational
EC assert data or stack-dump data is
accessible.
353
Informational
EC assert data and stack-dump data have
been cleared.
354
Informational
or warning
SAS topology has changed on a host port.
For example, the SAS cable connecting a
controller host port to a host has been
disconnected. This event is logged as
informational for a topology change where
at least one PHY goes “up.” This event is
logged as a warning for a topology change
where at least one PHY goes “down.”
355
Warning
The faceplate's debug button was found to
be stuck in the On position during boot up.
412
Warning
One disk in the specified RAID-6 vdisk failed.
The vdisk is operational with Degraded
health and status FTDN (fault tolerant with a
down disk).
Replace the down disk with a spare so the
system can start reconstructing the vdisk.
443
Warning
A firmware version mismatch has been
detected in an MSA70 drive enclosure. The
enclosure should be updated to the latest
supported version of firmware as soon as
possible.
In the drive enclosure all FRUs (I/O module,
fan, power supply, midplane, backplane,
and 7-segment LED) must be at a combined
proper firmware recipe. The two I/O
modules must be at equal firmware versions.
Any replaced MSA70 FRUs might have older
firmware that does not match an internally
defined recipe. Update the drive enclosure to
the latest firmware version to ensure all FRUs
are at the proper firmware level.
Table 14
Event code descriptions and recommended actions (continued)
Event
code
Event type
Description
Recommended action