HP 2000sa HP StorageWorks 2000 G2 Modular Smart Array reference guide (500911- - Page 93
The mirrored configuration retrieved by this, been changed.
View all HP 2000sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 93 highlights
Table 14 Event code descriptions and recommended actions (continued) Event Event type Description code Recommended action 75 Informational The specified volume's LUN has been If you want hosts to access the volume data unassigned because it conflicts with LUNs on the inserted disks, map the volume with a assigned to other volumes. This can happen different LUN. when disks containing data for a mapped volume have been inserted from another enclosure. 76 Informational The controller is using default configuration If you have just performed a firmware update settings. This event occurs on the first power and your system requires special up, and might occur after a firmware update. configuration settings, you must make those configuration changes before your system will operate as before. 77 Informational The cache was initialized as a result of power up or failover. 78 Warning The controller could not use an assigned spare for a vdisk because the spare's capacity is too small. This occurs when a vdisk's status becomes critical and all global spares are too small or (if dynamic spares are enabled) all disks are too small. Replace existing spares or add spares with enough capacity to replace the smallest disk in the vdisk. The vdisk size is limited by its disk with the least capacity. 79 Informational The trust vdisk operation has completed successfully. 80 Informational The controller has modified mode parameters on one or more disks. 81 Informational The current controller has unkilled the partner controller. The other controller will restart. 83 Informational The partner controller is changing state (shutting down or restarting). 84 Warning In an active-active configuration, the current Save the log files and contact a service controller has forced the partner controller to technician. fail over for the specified reason. 86 Informational The FC host port or disk parameters have been changed. 87 Warning The mirrored configuration retrieved by this controller from the partner controller has bad cyclic redundancy check (CRC). The local flash configuration will be used instead. The mirrored configuration is corrupted. Configuration data on the two controllers may be out of sync. Clear configuration may be needed to fully recover from this. 88 Warning The mirrored configuration retrieved by this controller from the partner controller is corrupt. The local flash configuration will be used instead. The mirrored configuration is corrupted. Configuration data on the two controllers may be out of sync. Clear configuration may be needed to fully recover from this. 89 Warning The mirrored configuration retrieved by this controller from the partner controller has a configuration level that is too high for the firmware in this controller to process. The local flash configuration will be used instead. This likely indicates that the current controller has down-level firmware. Update the firmware on the down-level controller. Both controllers should have the same firmware versions. When the problem is fixed, event 20 is logged. HP StorageWorks 2000 G2 Modular Smart Array Reference Guide 93