HP 2000sa HP StorageWorks 2312sa and 2324sa Modular Smart Array user guide (48 - Page 60
Power supply module voltage sensors, Description, Normal operating range, range, Warning
View all HP 2000sa manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 60 highlights
Table 9 Controller module temperature sensors (continued) Description Onboard temperature 2 Onboard temperature 3 (Capacitor temperature) CM temperature Normal operating Warning range operating range 0-70°C None 0-70°C None 5-50°C = 50°C Critical operating Shutdown values range None None None None = 55°C None When a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log. Table 10 Power supply temperature sensors Description Normal operating range Power Supply 1 temperature Power Supply 2 temperature -10-80°C -10-80°C Power supply module voltage sensors Power supply voltage sensors ensure that an enclosure's power supply voltage is within normal ranges. There are three voltage sensors per power supply. Table 11 Voltage sensor descriptions Sensor Event/Fault LED condition Power supply 1 voltage, 12V Power supply 1 voltage, 5V Power supply 1 voltage, 3.3V < 11.00V > 13.00V < 4.00V > 6.00V < 3.00V > 3.80V 60 Troubleshooting