HP 6100 HP 4x00/6x00/8x00 Enterprise Virtual Array User Guide (5697-0733, Marc - Page 120
Table 36 EVA4x00 power specifications - 208 Volts, In Rush Current
View all HP 6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 120 highlights
Table 36 EVA4x00 power specifications - 208 Volts Typical1 Specification Total System Wattage 2C1D 638 2C2D 1013 2C3D 1390 2C4D 1767 Total System BTU/hour 1729 3014 4300 5585 Input Current (A) - 1.6 2.6 3.5 4.4 Typical per line In Rush Current (A) 98 132 170 220 Failover Mode Input Current (A) - 2.7 4.3 5.9 7.5 Maximum per line 1 Typical is described as a system in normal steady state operation. (i.e., both PDUs operating normally, the array reading/writing to disk drives in a production environment). This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM drives. Table 37 EVA4x00 power specifications - 230 Volts Typical1 Specification Total System Wattage 2C1D 638 2C2D 1013 2C3D 1390 2C4D 1767 Total System BTU/hour 1729 3014 4300 5585 Input Current (A) - 1.5 2.4 3.3 4.2 Typical per line In Rush Current (A) 104 147 190 244 Failover Mode Input Current (A) - 2.6 4.1 5.5 7.1 Maximum per line 1 Typical is described as a system in normal steady state operation. (i.e., both PDUs operating normally, the array reading/writing to disk drives in a production environment). This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM drives. Table 38 EVA6x00 power specifications - 208 Volts Typical1 Specification Total System Wattage 2C4D 1837 2C5D 2214 2C6D 2590 2C7D 2967 2C8D 3344 Total System BTU/hour 6268 7553 8838 10124 11409 Input Current (A) - 4.6 5.5 6.5 7.4 8.4 Typical per line In Rush Current (A) 220 250 280 321 363 Failover Mode Input Current (A) - 7.8 9.4 11.0 12.6 14.2 Maximum per line 1 Typical is described as a system in normal steady state operation. (i.e., both PDUs operating normally, the array reading/writing to disk drives in a production environment). This data represents fully populated drive enclosures with 15K RPM disk drives. Other drive types may vary slightly. For example, if you are using 10K RPM drives, the power specifications will be approximately 20% less than the 15K RPM drives. 120 Regulatory notices and specifications