HP 6100 HP 4x00/6x00/8x00 Enterprise Virtual Array User Guide (5697-0733, Marc - Page 137
en.03 NONCRITICAL condition—Low voltage, Backplane conditions
View all HP 6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 137 highlights
To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. 1.2.en.03 NONCRITICAL condition-Low voltage This condition report indicates that an element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. This condition report remains active until the problem is corrected. To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. 1.2.en.04 CRITICAL condition-Low voltage This condition report indicates that an element voltage has reached the low voltage CRITICAL threshold. This condition report remains active until the problem is corrected. To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. 1.3.en.01 NONCRITICAL condition-High current This condition report indicates that an element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. This condition report remains active until the problem is corrected. To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. 1.3.en.02 CRITICAL condition-High current This condition report indicates that an element current has reached the high current CRITICAL threshold. This condition report remains active until the problem is corrected. To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. Backplane conditions IMPORTANT: Backplane NVRAM errors usually occur during manufacture. At this time they are identified and corrected. They rarely occur during normal operation. The format of a backplane condition report is 8.2.01.ec, where: • 8.2. is the backplane element type number • 01. is the two-character backplane element number • ec is the error code The only corrective action available for this error is to replace the drive enclosure. 8.2.01.10 NONCRITICAL condition-Backplane NVRAM read An invalid NVRAM read occurred and an automatic recovery process has begun. This condition report is active for 15 seconds. If the automatic recovery process does not correct the problem, record all six characters of the condition report, then contact your HP-authorized service representative. 8.2.01.11 NONCRITICAL condition-Backplane NVRAM write failure The system is unable to write data to the NVRAM. This problem prevents communication between elements in the enclosure. This condition report is active for 15 seconds. To correct this problem, record all six characters of the condition report, then contact your HP-authorized service representative. Correcting errors 137