HP 6100 HP 4x00/6x00/8x00 Enterprise Virtual Array User Guide (5697-0733, Marc - Page 134
Transceiver conditions, 0.F.en.01 CRITICAL condition—Transceiver incompatibility
View all HP 6100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 134 highlights
Transceiver conditions The format of a transceiver condition report is 0.F.en.ec, where: • 0.F. is the transceiver element type number • en. is the two-character transceiver element number (see Figure 43 (page 134)) • ec is the error code Figure 43 Transceiver element numbering 1. Transceiver 01 3. Transceiver 03 2. Transceiver 02 4. Transceiver 04 0.F.en.01 CRITICAL condition-Transceiver incompatibility The transceivers on this link are not the same type or they are incompatible with the I/O module. This error prevents the controller from establishing a link with the enclosure disk drives and eliminates the enclosure dual-loop capability. This error remains active until the problem is corrected. To correct this problem, record all six characters of the condition report, then contact your HP authorized service representative. 0.F.en.02 CRITICAL condition-Transceiver data signal lost This symptom can occur when a controller has been powered off or a cable has been removed from the transceiver. The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. This error remains active until the problem is fixed. To correct this problem, record all six characters of the condition report, then contact your HP authorized service representative. 0.F.en.03 CRITICAL condition-Transceiver fibre channel drive enclosure bus fault The system has detected a Fibre Channel drive enclosure bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. Complete the following procedure to correct this problem: 1. Record all six characters of the condition report. 2. Check all the transceivers and cables to ensure they are properly connected. 3. Check all the transceivers on the loop to ensure they are compatible with the I/O module. 4. If the problem persists, contact your HP authorized service representative. 0.F.en.04 CRITICAL condition-Transceiver removed The EMU detects that a transceiver has been removed. This error remains active until the problem is fixed. The error can be cleared by doing one of the following: 134 EMU-generated condition reports