HP 8/24 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 110
AG-1034, AG-1035, AG-1036, AG-1037
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
2 AG-1034 Severity INFO AG-1034 Message , [AG-1034], ,, INFO, ,F_Port cannot accept any more logins () . Probable Cause Indicates that the F_Port has already logged in the maximum number of devices. Recommended No action is required. Action Severity INFO AG-1035 Message , [AG-1035], ,, INFO, ,Device cannot login as ALPA value not available () . Probable Cause Indicates that a device has already used this ALPA value. Recommended No action is required. Action Severity INFO AG-1036 Message , [AG-1036], ,, WARNING, ,Port is connected to a Non-Brocade fabric with Persistent ALPA enabled. Check the admin guide for supported configuration . Probable Cause Indicates that one of the ports is connected to a non-Brocade fabric. Recommended No action is required. Action Severity WARNING AG-1037 Message Probable Cause , [AG-1037], ,, INFO, ,Trunked N_Port () going offline, if switchshow CLI for the connected fabric switch port displays Persistently disabled: Area has been acquired, then check cabling: all trunked ports should be in same ASIC Port Group . Indicates that the cabling is incorrect. 34 Fabric OS Message Reference 53-1001767-01