HP 8/24 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 171
CHASSIS System Messages, CHASSIS-1002
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
Chapter CHASSIS System Messages 15 CHASSIS-1002 Message , [CHASSIS-1002], ,, ERROR, , ki_gd_register_action failed with rc =. Probable Cause Indicates an internal error. Recommended Action For a bladed system, execute the slotPowerOff command and slotPowerOn commands on the blade to recover the system. For a non-bladed system, execute the fastBoot command on the switch to recover the system. Severity ERROR CHASSIS-1003 Message , [CHASSIS-1003], ,, ERROR, , Slot ENABLED but Not Ready during recovery, disabling slot = rval = . Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery. Recommended On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn Action command. On a Brocade 7500 or AP7600 switch, reboot or power cycle the switch. Severity ERROR CHASSIS-1004 Message , [CHASSIS-1004], ,, ERROR, , Blade attach failed during recovery, disabling slot = , rval = . Probable Cause Indicates that a blade has failed during failover or recovery. Recommended Action On a Brocade 24000 or 48000 switch, run the slotPowerOff command followed by the slotPowerOn command. On a Brocade 200E, 3250, 3850, 3900, 4012, 4016, 4018, 4020, 4024, 4100, 4900, 5000, 7500, or AP7600 switch, reboot or power cycle the switch. Severity ERROR Fabric OS Message Reference 95 53-1001767-01