HP 8/24 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 673
SSM System Messages, SSMD-1001
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 673 highlights
Chapter SSM System Messages 96 SSMD-1001 Message , [SSMD-1001], ,, ERROR, ,Failed to allocate memory: . Probable Cause Indicates that the specified function has failed to allocate memory. Recommended Action Check the memory usage on the switch using the memShow command. Restart or power cycle the switch. Severity ERROR SSMD-1002 Message , [SSMD-1002], ,, ERROR, ,Failed to initialize rc = . Probable Cause Indicates that an initialization of a module within the SSM has failed. Recommended Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS Action Command Reference Manual for more information on this command. Severity ERROR SSMD-1003 Message , [SSMD-1003], ,, ERROR, ,Failed to lock semaphore mutex: . Probable Cause Indicates that the specified function has failed to lock the mutex (semaphore). Recommended Restart or power cycle the switch. Action Severity ERROR SSMD-1004 Message , [SSMD-1004], ,, ERROR, ,Failed to unlock semaphore mutex: . Fabric OS Message Reference 597 53-1001767-01