19 CVLC-1030 Recommended Break the mirror and re-establish the mirror after rekey on primary LUN is complete. Action Severity WARNING CVLC-1030 Message , [CVLC-1030], ,, WARNING, , Primary LUN may be out of sync with mirror LUN.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates the manual rekey was completed on primary LUN. Recommended Action 1. Make the target ports of the mirror LUN offline to hosts. 2. Re-establish the mirror. 3. Once the mirror is in sync, split the mirror. 4. Bring back the target ports of the mirror LUN online. Severity WARNING CVLC-1031 Message , [CVLC-1031], ,, WARNING, , Primary LUN is restored from mirror LUN. LUN in read-only mode.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates a rekeyed primary LUN may have been restored from mirror LUN without synchronizing. Recommended Action 1. Create a new primary LUN. 2. Add it to its container with -newLUN option. 3. Using host based migration application, copy data from old to new primary LUN. Severity WARNING CVLC-1032 Message , [CVLC-1032], ,, INFO, , Secondary metadata for LUN has been restored.\nContainer: , Initiator: , LUN ID: . Probable Cause Indicates the host I/Os to secondary metadata region. Recommended No action is required. Action Severity INFO Fabric OS Message Reference 131 53-1001767-01