HP 8/24 Fabric OS Message Reference v6.4.0 (53-1001767-01, June 2010) - Page 130
ANV-1004, ANV-1005, ANV-1006, ANV-1007
View all HP 8/24 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 130 highlights
5 ANV-1004 ANV-1004 Message , [ANV-1004], ,, ERROR, , ,: Invalid DMA ch pointer, chan:, good_addr:0x bad_addr:0x. Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may degrade data traffic. Recommended Restart the system at the next maintenance window. If the problem persists, replace the blade. Action Severity ERROR ANV-1005 Message , [ANV-1005], ,, ERROR, ,,,: Memory allocation failed. Probable Cause Indicates the memory allocation failure in the software. Recommended Restart the system at the next maintenance window. If the problem persists, replace the CP blade. Action Severity ERROR ANV-1006 Message , [ANV-1006], ,, CRITICAL, , ,: HW ASIC Chip fault. Type = 0x, Error = . Probable Cause Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders the chip as not operational. Recommended Restart the system at the next maintenance window. If the problem persists, replace the blade. Action Severity CRITICAL ANV-1007 Message , [ANV-1007], ,, CRITICAL, , ,: ANVIL PASS 1 low buff pool fault: 0x. Probable Cause Indicates that Anvil Pass 1 is out of free buffer which might cause a chip fault. Recommended Reconfigure the testing setup. Action 54 Fabric OS Message Reference 53-1001767-01