22 EM-1070 EM-1070 Message , [EM-1070], ,, INFO, , Slot is being powered on. Probable Cause Indicates a blade is being intentionally powered on. Recommended No action is required. Action Severity INFO EM-2003 Message , [EM-2003], ,, ERROR, , has failed the POST tests. FRU is being faulted. Probable Cause Indicates that a field-replaceable unit (FRU) has failed the Power-On Self-Test. Refer to the /tmp/post[1/2].slot#.log file for more information on faults. To view this log file you must be logged in at the root level. The ID will be Switch for non-bladed systems. Recommended Action On bladed systems, try reseating the specified FRU. On nonbladed switches, reboot or power cycle the switch. If the problem persists: • Run the systemverification command to verify that the switch does not have hardware problems. To run this command root access is required. Refer to theFabric OS Reference Manual for more information on this command. • On bladed systems, replace the specified FRU; otherwise replace the switch. Severity ERROR 166 Fabric OS Message Reference 53-1001767-01