Page 29 highlights
Installation Procedures - All Deployments If both controllers are operational and both need servicing, schedule a maintenance window and perform the service as for a single-controller configuration. If both controllers are operational and one needs servicing, do the following to disable and then service the controller: Note: The MSA operates in a non-redundant mode during this procedure. a. Access a supported management utility for the MSA. b. In the utility, disable the controller to be removed. For details, see the utility online help or MSA user documentation. c. Wait for array controller disabled to display on the controller LCD panel. d. Remove the disabled controller for servicing or replacement. Caution: If an operational controller is removed without first being disabled, the active controller might halt. To clear this fault condition, you must power-cycle the MSA. For more information, see the HP StorageWorks 1500 Modular Smart Array Maintenance and Service Guide, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 29