Table 4, MSA1500 specifications, Parameter, Value

Page 35 highlights

Installation Procedures - All Deployments Table 4: MSA1500 specifications Parameter Dimensions: Height Width Depth Weight Shipping configuration Input Power: Rated Input Voltage Rated Input Frequency Maximum Rated Input Current Maximum Input Power Heat Dissipation (max) Temperature Ranges: Operating temperature Shipping temperature Relative Humidity (non-condensing): Operating Value 3.46 in (8.79 cm) 24.0 in (60.96 cm) 17.64 in (44.81 cm) 41.6 lb (18.9 kg) 100 to 240 VAC 47-63 Hz 1.3 A 160 W* 2187 Btu/hr* 50° F to 95° F (10° C to 35° C) [derated 1.8° F (1° C) per 1000 ft (304.8 m) of elevation to 10,000 ft (3048 m)] -22° F to 122° F (-30° C to 50° C) 10% to 90% Non-operating Maximum Wet bulb Temperatures: Long term storage up to 95% 84.2° F (29° C) Short term storage 86° F (30° C) *Input power and heat dissipation specifications are maximum values and apply to worst-case conditions at full-rated power supply load. The power/heat dissipation for your installation varies depending on the equipment configuration. HP StorageWorks 1500 Modular Smart Array Installation Guide 35

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Installation Procedures - All Deployments
35
HP StorageWorks 1500 Modular Smart Array Installation Guide
Table 4:
MSA1500 specifications
Parameter
Value
Dimensions:
Height
Width
Depth
3.46 in (8.79 cm)
24.0 in (60.96 cm)
17.64 in (44.81 cm)
Weight
Shipping configuration
41.6 lb (18.9 kg)
Input Power:
Rated Input Voltage
Rated Input Frequency
Maximum Rated Input Current
Maximum Input Power
100 to 240 VAC
47-63 Hz
1.3 A
160 W*
Heat Dissipation (max)
2187 Btu/hr*
Temperature Ranges:
Operating temperature
Shipping temperature
50
°
F to 95
°
F (10
°
C to 35
°
C)
[derated 1.8
°
F (1
°
C) per 1000 ft
(304.8 m) of elevation to 10,000 ft
(3048 m)]
-22
°
F to 122
°
F (-30
°
C to 50
°
C)
Relative Humidity (non-condensing):
Operating
Non-operating
10% to 90%
up to 95%
Maximum Wet bulb Temperatures:
Long term storage
Short term storage
84.2
°
F (29
°
C)
86
°
F (30
°
C)
*Input power and heat dissipation specifications are maximum values and apply to
worst-case conditions at full-rated power supply load. The power/heat dissipation
for your installation varies depending on the equipment configuration.