HP AD510A HP StorageWorks 1500 Modular Smart Array Installation Guide (355901- - Page 84

Installing the ACU-CLI on the servers (optional)

Page 84 highlights

Configuration Procedures - HP-UX Environments Installing the ACU-CLI on the servers (optional) To use the ACU-CLI to configure MSA storage, perform the following steps to install it on the servers: Note: ■ You must remove earlier versions of the ACU before installing later versions. ■ For information about using the ACU-CLI, see ACU-CLI online help, the HP-UX ACU-CLI readme file or release notes, or the HP Configuring Arrays Reference Guide. 1. Insert the Support Software CD in the CD-ROM drive of the server. Note: If you created a new Support Software CD from the Web, insert that CD in the CD-ROM drive of the server and do not use the shipping version of the CD. For more information, see: ■ "Determine which version MSA controller firmware to use" on page 17 ■ "Obtain desired controller firmware and Support Software CD versions" on page 61 2. From the console, mount the CD-ROM drive and navigate to the /HPUXACUCLI/HP-UX directory for your environment. 3. List the contents of the directory and identify the ACU-CLI depot file for your environment. 4. Copy the ACU-CLI depot file and its corresponding readme file to a temporary directory on the server. For example: # cp /HPACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47-1.depot .tmp 5. Install the ACU-CLI application using the swinstall command. For example: # swinstall -s /tmp/HPACUCLI_IA_v7.47-1.depot 6. Remove the Support Software CD from the CD-ROM drive. Note: To start the ACU-CLI, do the following from the console: Navigate to the /opt/compaq/hpacucli/bld directory, and then enter # ./hpacucli. 84 HP StorageWorks 1500 Modular Smart Array Installation Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

Configuration Procedures - HP-UX Environments
84
HP StorageWorks 1500 Modular Smart Array Installation Guide
Installing the ACU-CLI on the servers (optional)
To use the ACU-CLI to configure MSA storage, perform the following steps to
install it on the servers:
Note:
You must remove earlier versions of the ACU before installing later versions.
For information about using the ACU-CLI, see ACU-CLI online help, the HP-UX
ACU-CLI readme file or release notes, or the HP Configuring Arrays Reference
Guide.
1.
Insert the Support Software CD in the CD-ROM drive of the server.
Note:
If you created a new Support Software CD from the Web, insert that CD in the
CD-ROM drive of the server and do not use the shipping version of the CD. For more
information, see:
Determine which version MSA controller firmware to use
” on page 17
Obtain desired controller firmware and Support Software CD versions
” on page 61
2.
From the console, mount the CD-ROM drive and navigate to the
/HPUXACUCLI/HP-UX
directory for your environment.
3.
List the contents of the directory and identify the ACU-CLI depot file for your
environment.
4.
Copy the ACU-CLI depot file and its corresponding readme file to a
temporary directory on the server. For example:
# cp /HPACUCLI/HP-UX/IA64/HPACUCLI_IA_v7.47-1.depot .tmp
5.
Install the ACU-CLI application using the swinstall command. For example:
# swinstall -s /tmp/HPACUCLI_IA_v7.47-1.depot
6.
Remove the Support Software CD from the CD-ROM drive.
Note:
To start the ACU-CLI, do the following from the console: Navigate to the
/opt/compaq/hpacucli/bld
directory, and then enter
# ./hpacucli
.