HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 196
Table 8-2
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 196 highlights
Table 8-2 Class: SMX_Fan Property name Caption Description ElementName OperationalStatus[0] StatusDescriptions[0] HealthState Name CreationClassName DeviceID SystemCreationClassName SystemName Property implementation CIM_ManagedElement Short description of this fan from the name displayed by the MP or iLO. For example: Fan 1, Fan 1a. Description of this fan, including ElementName, FanType and StatusDescription[0]. For example: elementname provides cooling for fantype. statusdescription. where elementname represents the value of ElementName , fantype represents the corresponding string value of the FanType enumeration and statusdescription represents the value of StatusDescriptions[0] Short description of this fan from the name displayed by the MP or iLO For example: 1 Fan 1a. CIM_ManagedSystemElement 2 (OK)-if fan is operating properly 3 (Degraded)-if fan is degraded 6 (Error)-if fan has failed Description of the status of the fan correcponding to the OperationStatus Fan is operating properly-if OperationalStatus[0] is 2 (OK) Fan is degraded - if OperationalStatus[0] is 3 (Degraded Fan has failed-if OperationalStatus is 6 (Error) 5 (OK)-if fan is operating properly 10 (Degraded) if fan is degraded 20 (Major Failure)-if fan has failed Unique name fo this fan Fan n, where n represents the number of the fan instance. CIM_LogicalDevice SMX_Fan Unique identifier for this fan instance SMX_ComputerSystem.CreationClassName SMX_ComputerSystem.Name CIM_EnabledLogicalElement System Fan 196