HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 99
SMX_SAStorageVolumeIndication: Logical Drive, Status Changed to ERROR
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 99 highlights
4-4-6 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Table 4-91 SMX_SAStorageVolumeIndication: Logical Drive Status Changed to ERROR Property name IndicationIdentifier PerceivedSeverity IndicationTime Description AlertingMangedElement AlertingElementFormat AlertType EventID EventTime ProviderName RecommendedActions SystemName SystemCreationClassName Summary EventCategory ProbableCause ProbableCauseDescription NetworkAddresses OSType OSVersion ProviderVersion SystemFirmwareVersion Property implementation CIM_Indication GUID string generated at the time of indication 5 (Major) Time of indication CIM_AlertIndication A logical drive status has changed to Error. WBEM Path of SMX_SAStorageVolume Class 2 (CIMObjectPath) 5 (Device Alert) 102 Time of the event or time of the indication if event time unknown HP Smart Array Check for failed or removed physical drives. Name of the computer system generating the indication CreationClassName of the computer system generating the indication HP_AlertIndication Logical drive status error 6 (Primary Storage) 86 (Disk Failure) Logical Drive Status Changed to Error Contains a list of all the IP addresses of the computer system generating the indication SMX_OperatingSystem.OSType The operating system version of the computer system generating the indication in the following format: .. 2.2.0.0 Firmware version of the computer system generating the indication Smart Array 99