HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 267
Table 12-20
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 267 highlights
Table 12-20 Class: SMX_MemoryRedundancySet Property name RedundancyStatus OperatingSpeed AvailableMemory TotalMemory CurrentConfiguration Property implementation The current memory redundancy status as follows: • 2 (Fully Redundant)-System is operating properly in the Advanced Memory Protection mode given in the TargetConfiguration property. • 3 (Degraded Redundancy)-Degraded Redundancy can occur in either of two conditions: ○ System is not operating in the TargetConfiguration mode (the CurrentConfiguration mode does not match the TargetConfiguration mode). ○ System is operating in the TargetConfiguration mode but memory module(s) have correctable errors exceeding the condition for pre-failure warranty. HP_MemoryRedundancySet The current operating speed of the Advanced Memory Protection subsystem in MHz The size of the memory as seen by the operating system in MB Total size of memory as seen by the operating system and memory used for Advanced Memory Protection configurations in MB The current operating mode of the Advanced Memory Protection system. The value in this property corresponds to the value populated in the property TypeOfSet[0]. CurrentConfiguration is one of the following: • Advanced ECC, when the system is operating in Advanced ECC mode • RAID, when the system is operating in RAID (XOR) mode • Mirrored, when the system is operating in Mirrored mode • Online Spare, when the system is operating in Online Spare mode • Lockstep, when the system is operating in Lockstep mode System memory 267