HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 274
Table 12-31, Table 12-32
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 274 highlights
Table 12-31 SMX_MemoryIndication: Memory Board Error Property name PerceivedSeverity Description Property implementation CIM_Indication 5 (Major) CIM_AlertIndication A memory board has an error. (MemoryBoardCaption) where MemoryBoardCaption is the SMX_MemoryBoard.Caption for the failing memory board. Table 12-32 SMX_MemoryIndication: Memory Redundancy Degraded Property name AlertingManagedElement AlertingElementFormat AlertType EventID ProviderName RecommendedActions Summary EventCategory ProbableCause ProbableCauseDescription PerceivedSeverity Description AlertingManagedElement AlertingElementFormat AlertType Property implementation WBEM Path of SMX_MemoryBoard instance representing the memory board 2 (CIMObjectPath) 5 (Device Alert) 2 SMXMemory Check the memory configuration and replace the memory board and memory modules as necessary. HP_AlertIndication Memory board error 3 (Memory) 1 (Other) Memory B CIM_Indication 5 (Major) CIM_AlertIndication The Advanced Memory Protection (AMP) system is operating with degraded redundancy. The targeted configuration has degraded or is operating with memory modules that have failed or predicted to fail. (TargetConfiguration/CurrentConfiguration) where TargetConfiguration is SMX_MemoryRedundancySet.TargetConfiguration. WBEM Path of SMX_MemoryRedundancySet instance representing the Memory Redundancy. 2 (CIMObjectPath) 5 (Device Alert) System memory 274