HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 88
HP_DeviceIndication: Physical Drive Status, Changed to ERROR
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Table 4-86 HP_DeviceIndication: Physical Drive Status Changed to OK Property name SystemVirtualSerialNumber SystemVirtualUUID HWFirmwareVersion HWLogicalLocation HWPhysicalLocation HWSerialNumber DeviceModel DeviceControllerLogicalLocation VariableNames VariableTypes[] VariableValues[] Property implementation Conditional property containing the virtual system serial number string when running in a Virtual Connect environment Conditional property containing the virtual system UUID when running in a Virtual Connect environment HP_HardwareIndication Physical Disk F/W version string Physical Disk Location string For example, Port:1E Box: 1 Bay 5 Physical Location of the Failed Drive (Bay Number) Physical Disk Serial Number HP_DeviceIndication Physical Disk Model string Controller Location For example, SmartArray 642 in Slot 2 Failure Description DriveInterface LastFailureDescription String (1) uint16 (4) FailureDescription short description of the failure Drive interface HPSA_DiskDrive.DriveInterface LastFailureDescription - last failure reason string from the drive. HPSA_DiskDrive.OperationalStatus[1] 4-4-2 HP_DeviceIndication: Physical Drive Status Changed to ERROR Table 4-87 HP_DeviceIndication: Physical Drive Status Changed to ERROR Property name IndicationIdentifier IndicationIdentifier Property implementation CIM_Indication GUID string generated at indication CIM_Indication GUID string generated at the time of indication Smart Array 88