HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 45
Logical Drive Non-Failure Problem, Storage Enclosure Non-Failure Problem, Array is operating
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 45 highlights
Table 4-2 Class: SMX_SAArraySystem (CIM_ComputerSystem) Property name ElementName OperationalStatus[0] StatusDescriptions[0] EnabledDefault EnabledState RequestedState CreationClassName Name NameFormat Property implementation Controller/Storage System name and location Examples: Smart Array in Slot=3, for internal Smart Array Embedded Controller=7 for embedded controller where 7 is the internal identifier for the embedded controller CIM_ManagedSystemElement Overall status of the Array System and attached devices. This is calculated per the algorithm desciribed in the HP Smart Array Profile. 0 (Unknown) 2 (OK) 3 (Degraded) 6 (Error) More info for OperationalStatus result. This provides a short decription to identify who is contributing to nonOK status. Examples: Controller Failure Logical Drive Failure Storage Enclosure Failure Controller Non-Failure Problem Physical Drive Non-Failure Problem Logical Drive Non-Failure Problem Storage Enclosure Non-Failure Problem Array is operating properly Array status is unknown CIM_LogicalElement CIM_EnabledLogicalElement 2 (Enabled) 5 (Not Applicable) 12 (Not Applicable) CIM_System SMX_SAArraySystem Controller Serial Number Note: EMBEDDED- is reported if there is no Serial Number for device is local i.e embedded on motherboard. PCISLOT- is reported if there is no Serial Number for device is local i.e.PCI occupies slot. Other Smart Array 45