HP BL680c HP Insight Management WBEM Providers for HP integrated VMware ESXi D - Page 269
SMX_MemoryRedundan
UPC - 884420396314
View all HP BL680c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 269 highlights
Table 12-21 Class: SMX_MemoryCollection Property name GroupOperationalStatus GroupStatusDescriptions Property implementation Enumerator indicating the group operational status of the memory collection. The status is determined as follows: • If an instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined from the property SMX_MemoryRedundancySet.RedundancyStatus. • If no instance of SMX_MemoryRedundancySet exists, GroupOperationalStatus[0] is determined by the worst-of algorithm for physical memory boards and memory modules. For details, see the Memory Collection Status. GroupStatusDescriptions[0] contains descriptive text per GroupOperationalStatus[0]: • Memory collection status: OK • Memory collection status: Degraded • Memory collection status: Unknown HP_MemoryCollection Table 12-22 Memory Collection Status RedundancyStatus worst from OperationalStatus[0], SMX_MemoryRedundan SMX_MemoryBoard cySet 2 (Fully Redundant) - 3 (Degraded Redundancy) - - 2 (OK) - 2 (OK) - 2 (OK) - 3 (Degraded) - 3 (Degraded) - 3 (Degraded) - 0 (Unknown) - 0 (Unknown) - 0 (Unknown) worst OperationalStatus[0], SMX_MemoryModule - - 2 (OK) 3 (Degraded) 0 (Unknown) 2 (OK) 3 (Degraded) 0 (Unknown) 2 (OK) 3 (Degraded) 0 (Unknown) GroupOperationalStatus [0] 2 (OK) 3 (Degraded) 2 (OK) 3 (Degraded) 0 (Unknown) 3 (Degraded) 3 (Degraded) 3 (Degraded) 0 (Unknown) 3 (Degraded) 0 (Unknown) System memory 269