HP Integrity Superdome 2 8/16 HP Integrity Superdome 2 Onboard Administrator U - Page 120

Interconnect Bay Status tab, Status information, Diagnostic Information

Page 120 highlights

Interconnect Bay Status tab Status information Item Status Thermal Status Powered Description The overall status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. The thermal status of the interconnect device. Possible values are Unknown, OK, Degraded, and Failed. The power state of the interconnect device. Possible values are On or Off. Diagnostic Information Row Device Identification Data Management Processor Temperature Overheat Check Device Operational Device Degraded Description Contains information on model name, part number, serial number, and other information used to identify the device. This data is also called FRU data. Device identification data error displays if the data is not present or not readable by the Onboard Administrator. Management processor is not responding. Possible values are OK or Error. Temperature is above the warning threshold. Possible values are OK or Temperature Warning. Temperature is above the danger threshold. Possible values are OK or Critical temperature threshold reached. Device has failed; status was not requested by the Onboard Administrator. Possible values are OK or Error. Device has failed; status was requested by the Onboard Administrator. Possible values are OK or Error. 120 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197

Interconnect Bay Status tab
Status information
Description
Item
The overall status of the interconnect device. Possible values are Unknown, OK, Degraded,
and Failed.
Status
The thermal status of the interconnect device. Possible values are Unknown, OK, Degraded,
and Failed.
Thermal Status
The power state of the interconnect device. Possible values are On or Off.
Powered
Diagnostic Information
Description
Row
Contains information on model name, part number, serial
number, and other information used to identify the device.
Device Identification Data
This data is also called FRU data. Device identification
data error displays if the data is not present or not readable
by the Onboard Administrator.
Management processor is not responding. Possible values
are OK or Error.
Management Processor
Temperature is above the warning threshold. Possible
values are OK or Temperature Warning.
Temperature
Temperature is above the danger threshold. Possible values
are OK or Critical temperature threshold reached.
Overheat Check
Device has failed; status was not requested by the Onboard
Administrator. Possible values are OK or Error.
Device Operational
Device has failed; status was requested by the Onboard
Administrator. Possible values are OK or Error.
Device Degraded
120
Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices