Device Bays Standard tab, Interconnect Bays tab, the HP Superdome 2 Onboard Administrator logs
View all HP Integrity Superdome 2 8/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 86 highlights
Typical use cases involving bay to bay dependencies that can be resolved by enabling the enclosure power delay feature include: • Boot from network- Network interconnects must complete power on self test prior to servers that are configured to boot from the network (for example, PXE or iSCSI). • Boot from SAN- SAN interconnects must complete power on self test prior to servers that are configured to boot from SAN • Critical service dependencies controlled by a server such as DHCP or licensing • Storage servers must be operational prior to servers requiring those resources The delay time setting must be determined empirically since some dependencies are outside the enclosure (boot from SAN might require additional delay to enable the datacenter SAN storage system to power on). Each interconnect module has different power on timing before it is operational. The timer used for power delay is started at the time the Onboard Administrator enters the first system log message during Onboard Administrator initialization indicated by the system log message Kernel: Network link up. When the HP Superdome 2 Onboard Administrator indicates PowerDelay has been initiated for the selected devices in the system log, the configured delay times for each bay are used to determine when that component is turned on. After the selected delay time has elapsed, that component is turned on. Valid settings for each bay are: Disabled, Enabled and No Poweron. • Disabled - Disables powerdelay for this bay. HP Superdome 2 Onboard Administrator grants power to this bay based on its power settings: for a device configured to auto power-on, the device is granted power following an enclosure power cycle after all the Onboard Administrator configuration checks are complete. • Enabled- Enables powerdelay for this bay. HP Superdome 2 Onboard Administrator turns on this bay based on the number of seconds elapsed following the detection of an enclosure power cycle event. • No Poweron- Prevents component power on for the bays with this configuration until after the HP Superdome 2 Onboard Administrator logs PowerDelay has completed for the selected devices. At this time, if the device is configured to auto power-on, the device grants power following an enclosure power cycle after all the Onboard Administrator configuration checks are complete. If the device is configured to disable auto poweron, the device remains off following an enclosure power cycle independent of the setting of power delay for that bay. Device Bays Standard tab The Device Bays Standard tab indicates the current settings for all the primary bays based on the type of enclosure. To change a setting on a particular device bay, use the menu under the Enabled column and select Enabled, Disabled or No Poweron. If Enabled is selected, a power delay in seconds must be entered in the Delay column for this bay. The minimum value is 1 second; the maximum value is 3600 seconds. Interconnect Bays tab Interconnect bays by default are for auto power-on. Enabling and setting a power delay for an interconnect bay delays the power on of that bay following an enclosure power cycle event. Column Bay Device Description Bay number of the device. The type of device in the bay, or Absent if no device is installed in the bay 86 Configuring HP Integrity Superdome 2 compute enclosures and enclosure devices