HP J8698A User Manual - Page 67

Replacing the Management Module Battery, Installing a New Battery - end of life

Page 67 highlights

WARNING Replacing Components Replacing the Management Module Battery Replacing the Management Module Battery The battery on the management module is used to keep time for the internal switch clock. There is no indicator LED for when the battery dies. The only indication will be the internal clock will not keep the correct time. ■ The battery requires special handling at end-of-life. The battery can explode or cause burns if disassembled, charged, or exposed to water, fire or high temperature. After replacing the battery, properly dispose of used battery according to instructions. ■ There is a risk of explosion if the battery is replaced by an incorrect type. Ensure to replace the battery with the same type. ■ To avoid shorting of battery, remove and properly dispose of battery before returning the Management Module for repair. Installing a New Battery To install (or replace) a New Battery: 1. Using either a flat-bladed or Torx T-10 screwdriver loosen the retaining screws securing the management module. (You cannot access the battery when the management module is installed.) 2. Using the extractor handles, pull the module out from the slot. Battery Replacing Components Figure 4-5. Battery Location on Management Module 4-7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118

4-7
Replacing Components
Replacing the Management Module Battery
Replacing Components
Replacing the Management Module Battery
The battery on the management module is used to keep time for the internal
switch clock. There is no indicator LED for when the battery dies. The only
indication will be the internal clock will not keep the correct time.
WARNING
The battery requires special handling at end-of-life. The battery
can explode or cause burns if disassembled, charged, or exposed
to water, fire or high temperature. After replacing the battery,
properly dispose of used battery according to instructions.
There is a risk of explosion if the battery is replaced by an
incorrect type. Ensure to replace the battery with the same type.
To avoid shorting of battery, remove and properly dispose of
battery before returning the Management Module for repair.
Installing a New Battery
To install (or replace) a New Battery:
1.
Using either a flat-bladed or Torx T-10 screwdriver loosen the retaining
screws securing the management module. (You cannot access the battery
when the management module is installed.)
2.
Using the extractor handles, pull the module out from the slot.
Figure 4-5.
Battery Location on Management Module
Battery