HP ProLiant DL380p Configuring Arrays on HP Smart Array Controllers Reference - Page 64

Viewing enclosure information, Viewing physical drives for an HBA, Viewing SSD physical drives

Page 64 highlights

ctrl slot=1 ld 3 modify drives=2e:1:1-2e:1:4 ctrl slot=1 ld 3 modify drives=? // shows the available drives You can use the drivetype parameter to specify the drive interface type. When selecting all physical drives, and multiple drive types exist, you must specify the drive interface type. Mixed drives are not allowed on the same array or logical drives. If all drives on a controller are the same type, this parameter is not needed. For drivetype, use one of the following valid options: [drivetype=sas | satalogical | sata | saslogical | parallelscsi | ss_sas | ss_sata | ?] Command examples: controller slot=5 ld 1 modify drives=? drivetype=sas controller slot=5 array A modify drives=? drivetype=ss_sas Viewing enclosure information The enclosure keyword is a valid target for the show command, and it outputs the storage enclosure information. Syntax: enclosure [ all | port:box | serialnumber=xxx ] show [ detail | status ] where the target can be any valid storage controller. Example commands: controller slot=5 enclosure all show controller slot=5 enclosure 4E:1 show detail controller slot=5 enclosure serialnumber=UAB123456 show status Viewing physical drives for an HBA The nonsa keyword shows the physical drives behind an HBA or "non-smart array." Syntax: nonsa show [ssdinfo] Command examples: controller nonsa show controller nonsa show ssdinfo Viewing SSD physical drives The ssdphysicaldrive keyword is a valid target for the show command, and it outputs the solid state physical drives on the specified controller. Syntax: ssdpd all show [detail] where the target is any valid controller. Example commands: controller slot=5 ssdpd all show controller slot=5 ssdpd all show detail Viewing SSD information The ssdinfo keyword provides a summary for solid state drives for the specified controller. HP Array Configuration Utility 64

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128

HP Array Configuration Utility
64
ctrl slot=1 ld 3 modify drives=2e:1:1-2e:1:4
ctrl slot=1 ld 3 modify drives=? // shows the available drives
You can use the
drivetype
parameter to specify the drive interface type. When selecting all physical
drives, and multiple drive types exist, you must specify the drive interface type. Mixed drives are not allowed
on the same array or logical drives. If all drives on a controller are the same type, this parameter is not
needed.
For
drivetype
, use one of the following valid options:
[drivetype=sas | satalogical | sata | saslogical | parallelscsi | ss_sas |
ss_sata | ?]
Command examples:
controller slot=5 ld 1 modify drives=? drivetype=sas
controller slot=5 array A modify drives=? drivetype=ss_sas
Viewing enclosure information
The
enclosure
keyword is a valid target for the
show
command, and it outputs the storage enclosure
information.
Syntax:
enclosure [ all | port:box | serialnumber=xxx ] show [ detail | status ]
where the target can be any valid storage controller.
Example commands:
controller slot=5 enclosure all show
controller slot=5 enclosure 4E:1 show detail
controller slot=5 enclosure serialnumber=UAB123456 show status
Viewing physical drives for an HBA
The
nonsa
keyword shows the physical drives behind an HBA or "non-smart array."
Syntax:
<target> nonsa show [ssdinfo]
Command examples:
controller nonsa show
controller nonsa show ssdinfo
Viewing SSD physical drives
The
ssdphysicaldrive
keyword is a valid target for the
show
command, and it outputs the solid state
physical drives on the specified controller.
Syntax:
<target> ssdpd all show [detail]
where the target is any valid controller.
Example commands:
controller slot=5 ssdpd all show
controller slot=5 ssdpd all show detail
Viewing SSD information
The
ssdinfo
keyword provides a summary for solid state drives for the specified controller.