- HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 1
HP ProLiant SL390s G7 2U half width Server Maintenance and Service Guide Part number 614097-001 September 2010 (First edition) - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 3
...28 Post-installation instructions...28 Server Warnings and Cautions ...28 Symbols on Equipment ...29 Powering Down the Server...30 System tray Removal and Replacement panel LED indicators ...70 Rear panel LED indicators ...73 Diagnostic tools ...75 Troubleshooting resources...75 Contents 3 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 4
...75 Integrated Management Log ...76 Array Diagnostic Utility...76 HP Systems Insight Manager ...76 HP Insight Remote Support software ...76 USB support and functionality...77 USB support ...77 Internal USB functionality ...77 Internal SD support...78 Physical and Operating Specifications 79 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 5
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 6
pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 7
due categorie di parti CSR: • Obbligatorie - Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio. • Opzionali - Parti la cui riparazione da parte del cliente è facoltativa - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 8
Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 9
componentes CSR se clasifican en dos categorías: • Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 10
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSRonderdeel, verzendt - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 11
diretamente ao cliente. Existem duas categorias de peças CSR: • Obrigatória - Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço. • Opcional - Peças cujo reparo feito pelo cliente é opcional - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 12
Customer self repair 12 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 13
Customer self repair 13 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 14
Customer self repair 14 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 15
Customer self repair 15 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 16
parts catalog Mechanical components Item 1 2 3 4 5 6 7 8 9 10 Description Front GPU bracket SL390s G7 2U left tray Left front I/O bezel front PCIe bracket Top power bracket Single GPU bottom bracket HDD cage Right front I/O bezel SL390s G7 2U right tray Top cover of power supply Spare part number - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 17
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 18
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 19
Illustrated parts catalog 19 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 20
System components Item Description 1 SL390s G7 System Board 2 PCA x24 riser card X16 riser card 3 Rear GPU riser card 4 Front GPU riser card 5 Front PCIe card 6 Hard Drive, SSD 64GB SFF Hard Drive, SSD 60GB SFF Hard Drive, SSD 120GB SFF Hard Drive, SAS 300GB 15K - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 21
7.2K SFF Hard Drive SATA 300GB 10K SFF 8 IOH mezz card 9 IB Enablment card 10 HDD backplane 11 Personality board GPU power board 12 Processors ,Optional Series Processor Intel X5680 3.33GHz/1333/12M/6c/6.4 QPI/130W Spare Part Number Customer Self Repair 575053-001 Optional2 575054-001 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 22
4GB DIMM PC3-8500R 4GB DIMM PC3-8500R 8GB 14 Processor Heat Sink 15 GPU, optional HP Tesla M1060 2-Slot Passive Module HP Tesla M2050 3GB Module (SH885A) HP Tesla M2050 3GB Module (SH885B) HP Tesla M2070 6GB Module 16 SL390s G7 System Board 17 System Fan, Non Redundant System Fan, Redundant 18 1200 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 23
RDM cable 623164-001 Optional2 1Mandatory-Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts for which customer self repair is optional. These parts are also designed for - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 24
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 25
Illustrated parts catalog 25 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 26
-1518. • In Canada, call 1-800-263-5868. • In other locations, refer to the HP website at http://www.hp.com/. For HP technical support: • In North America: ○ Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 27
instructions correspond to the numbered labels on the related figure (i.e., label 1 corresponds to step a, label 2 corresponds to step b, etc.). The procedures described in this section assume that the server HP ProLiant SL390s G7 2U half width server Easy Set-up CD • IPMI Event Log • Diagnostics - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 28
the power button on the front panel to turn on the server. NOTE: The HP ProLiant SL390s G7 2U half width server supports up to four 750-W or 1200-W power supply units. Server Warnings and Cautions Before installing a server, be sure that you understand the following warnings and cautions. WARNING - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 29
the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. CAUTION: The following rack-mount instructions shall of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. To reduce the risk of injury from - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 30
observe local occupational health and safety requirements and guidelines for manual material handling. These symbols, on power supplies or server. System tray Removal and Replacement Procedures The system tray is removable for a server component removal and replacement. To remove the system tray - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 31
Figure 1 Removing the left server Figure 2 Removing the right server To replace the system tray: 1. Insert the system tray into the chassis. 2. Rotate the tray handle to lock the power connector. Removal and Replacement Procedures 31 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 32
Figure 3 Installing the left server Figure 4 Installing the right server Drives The server supports 6 drive bays for 2.5-inch SFF or SSD hard disk drives. Cable Management Always follow good cable management practices when working inside the computer. • Keep cables - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 33
provides information about cable connector. Table 1 Cable connection Cable MB power cable ((Leftand Right tray) RPS cable (left and right tray) Front_riser power cable((left and right tray) 4 HDD_BP power cable(left and right tray) mini SAS to 4x7pin SATA cable From J2 on Personality Board J3 on - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 34
and 8pin bottom GPU 2 x 8pin top front/rear GPU Hard Drives One SL390s G7 2U half width server tray can accommodate tray, and 4 SFF hotplug hard disk drives or SSDs on the front of the tray. One chassis can accommodate 4 2U server trays for up to 24 SFF hard disk drives or SSDs. The server supports - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 35
Description 1 Hard Drive 1 2 Hard Drive 2 3 Hard Drive 3 4 Hard Drive 4 5 Hard Drive 5 6 Hard Drive 6 To remove hard drive: CAUTION: HP ProLiant SL390s G7 2U half width Server supports disk drive hot-swapping. To avoid hand contact with an electrical hazard, do not remove more than one - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 36
bay. Figure 8 Removing the hard drive assembly 1. Press the latch to release the hard drive assembly. 2. Remove the hard drive assembly out of the tray. Figure 9 Removing the hard drive assembly To install hard drive: 1. Push the hard drive assembly into the drive bay until it stops. 2. Press the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 37
Figure 10 Installing the hotplug hard disk drives or SSDs on hotplug driver carrier on the front of the tray 1. Insert the hard drive assembly into the chassis and make sure the notch on the carrier locked on the tray. Figure 11 Installing the non-hotplug SFF hard disk drives or SSDs on quick - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 38
. Figure 13 Installing the HDD backplane System Board Configuration Processor HP ProLiant SL390s G7 2U Server, with 4 Nodes, supports eight -processor operation. With two processors installed, each Node supports boot functions through the processor installed in processor Removal and Replacement - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 39
2 and provides a processor failure message. The processor socket supports Quad-Core Intel Nehalem and Westmere Processors High Wattage 130W,95W use processors of the same speeds or cache sizes to prevent possible server malfunction. Figure 14 Processor locations Item Description 1 Processor 1 2 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 40
Figure 15 Removing the heat sink assembly IMPORTANT: If the heat sink has been removed for any reason on a previously installed processor, it is critical that you apply more thermal interface material to the integrated heat spreader on the processor to ensure proper thermal bonding between the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 41
processor into the socket. The processor and system board spare part kits contain the processor install tool and instructions on how to use the tool. It is important to follow the instructions to prevent damage to the pins in the processor socket. To install the new processor: 1. Open the processor - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 42
Figure 19 Installing the processor 4. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool. Figure 20 Removing the processor installation tool 5. Close the processor socket retaining bracket and the processor - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 43
Wipe the contact surfaces several times to make sure that no particles or dust contaminants are evident. CAUTION: HP recommends using Shin-Etsu X-23-7783D thermal grease compound for your ProLiant server. 2. Apply all the grease to the top of the processor in one of the following patterns to insure - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 44
breaking off. A maximum torque of 4 in-Ib is set for the system. Figure 23 Installing the heat sink Memory HP ProLiant SL390s G7 2U half width server has 12 DIMM slots that support up to 96 GB maximum system memory. You must adhere to the following guidelines when adding or replacing memory modules - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 45
Figure 24 DIMM slots Figure 25 DIMM Order To remove memory module: 1. Completely open the holding clips securing the module. 2. Gently pull the memory module upward to remove it from the slot. Removal and Replacement Procedures 45 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 46
the orientation of the module and reinsert. If the holding clips do not close, the module is not inserted correctly. NOTE: The ProLiant SL390s G7 2U half width server supports up to 12 memory modules. Install them in the DIMM slots starting from the DIMM 1 slot. Removal and Replacement Procedures 46 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 47
PCI Expansion Slots There is one x 16 or x24 PCIe riser slot on the system boards. Figure 28 System board PCI expansion slot on each tray 1. Install the riser card to the front PCIe bracket. Figure 29 Installing the riser card 2. Install an optional PCIe card to the PCA x24 riser - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 48
optional front PCIe card to the PCA x24 riser assembly 3. Install the front x24 riser card assembly to the tray: Figure 31 Installing front x24 riser card assembly to the tray NOTE: Reverse the above steps for removal procedures. Battery-backed write cache procedures 1. Align the BBWC bracket to the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 49
Figure 32 Installing the BBWC bracket 2. Install the BBWC into the tray and slide it in the direction of the arrow. Figure 33 Installing the BBWC 3. Connecting the BBWC cable with the smart array controllers. Removal and Replacement Procedures 49 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 50
Cable routing System Battery The server uses nonvolatile memory that battery: • Replace the battery with the same type as the battery recommended by HP. Use of another battery may present a risk of fire or explosion. • A according to manufacturer's instructions. Removal and Replacement Procedures 50 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 51
when the battery is removed. You must reconfigure BIOS settings whenever you replace the battery. NOTE: If the server no longer automatically displays the correct date and time that secure the system board to the tray. 2. Release the system board from the tray. Removal and Replacement Procedures 51 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 52
system board is removed in the future, you must keep them for future use. To replace the system board: 1. Put the system board in the tray. The screw holes on the tray should align with the holes on the system board. 2. Fasten the screws to secure the system board to the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 53
holes on the personality board. 2. Fasten the screws to secure the personality board to the tray. Figure 40 Installing the personality board Power Supply Unit (PSU) Located on the rear panel of the server power supply is a standard ranging 750 watt or 1200 watt PSU with PFC (power factor correction - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 54
shock hazards and/or damage to the equipment. • Installation of power supply units should be referred to individuals who are qualified to service server systems and are trained to deal with equipment capable of generating hazardous energy levels. • DO NOT open the power supply unit. There are no - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 55
Figure 43 Removing the Power supply To replace the PSU Backplane: 1. Remove the top cover from the power supply cage. 2. Install the PSU Backplane. 3. Reinstall the top cover to the power supply cage. Figure 44 Installing the PSU Backplane To replace the power supply: 1. Align the power supply edge - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 56
Figure 45 Installing the power supply System Fan The server has eight system fans located on the rear panel of chassis. The figure below identifies the system fans by their device number. Figure 46 System - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 57
Item Description 6 Fan 6 7 Fan 7 8 Fan 8 A new system fan can be installed to allow the server to operate properly in case a default system fan becomes defective. To remove the system fan: 1. Squeeze the two release tabs on the system fan together - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 58
the screws securing the HDD module to the tray. 2. Remove the HDD module out of the tray. Figure 49 Removing the HDD module To remove the 2 GPU bracket: 1. Unfasten the screws securing the 2 GPU bracket to the tray. 2. Remove the 2 GPU bracket out of the tray. Removal and Replacement Procedures 58 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 59
50 Removing the 2 GPU bracket Installing the Single GPU Option Kit 1. Install the GPU extension bracket to the M2050 , M1060 GPU and M2070: NOTE: Skip this step if installing an M1060 GPU. Figure 51 Installing the GPU extension bracket 2. Install the GPU on the rear GPU assembly and fasten the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 60
Figure 52 Installing the GPU on the rear GPU assembly 3. Insert a,b,c,d cables on the rear GPU assembly: Figure 53 Connecting the cables on the rear GPU assembly 4. Install the rear GPU assembly on the bottom of 2U tray and fasten the screws to secure it to the tray: Removal and Replacement - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 61
on the bottom of 2U tray 5. Connect the PCA x24 riser card and the rear GPU assembly with a.b.c.d 4 cables, make sure the cables connect correctly: Figure 55 Connecting the cables Installing the 2 GPU Riser Option Kit 1. Install the front GPU riser card to the 2 GPU bracket: Removal and Replacement - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 62
front riser card. b. Fasten the screws to secure the IOH mezz assembly to the 2 GPU bracket. Figure 57 Installing the IOH mezz assembly to the 2 GPU bracket Installing the 2 GPU bracket assembly 1. Install the GPU extension bracket to the M2050 and M2070 GPUs: NOTE: Skip this step if installing an - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 63
Figure 58 Installing the GPU extension bracket 2. Install the GPUs to the 2 GPU bracket: Figure 59 Installing the GPUs on the 2 GPU bracket 3. Install the 2 GPU bracket into the tray and fasten the screws to secure it to the tray: Removal and Replacement Procedures 63 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 64
Figure 60 Installing the 2 GPU bracket into the tray 4. Reinstall the HDD module and fasten the screws: Figure 61 Reinstalling the HDD module Removal and Replacement Procedures 64 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 65
, and LED indicators located on the front panel, rear panel of the HP ProLiant SL390s G7 2U half width Server. Connectors and Components Front Panel Components Figure 62 Front panel components of SL390s G7 2U server system Item 1 2 3 4 5 6 7 8 9 10 11 Description VGA port Serial port SFP PLUS - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 66
Description 12 Power LED/SW 13 HDD3 14 HDD4 15 iLO3 network port Rear panel components Figure 63 Rear panel components of SL390s G7 2U server system Item 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Description Power Supply 1 Power Supply 2 Power Supply 3 Power Supply 4 UID LED/SW APM connector Fan - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 67
System board components Figure 64 System board components Item Designator Description 1 J38 Serial port 2 SW3 Power LED/SW 3 J30 4 J41 QSFP cage Top: NIC port1 Bottom: NIC port2 5 J37 Top: ILO port Bottom: USB 2.0 Port 6 SW4 UID LED/SW 7 J12 Micro SD card 8 U2 IB 9 U84 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 68
Item 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Designator Description @U10, @U22, @U41, @U51, @U12, @U10, @U14, @U11 CPU2 VRD and CPU1 DIMM VRD XU2 Processor 2 socket J1 CPU1 DDR3 DIMM slot J2 CPU1 DDR3 DIMM slot J4 CPU1 DDR3 DIMM slot J5 CPU1 DDR3 DIMM slot J7 CPU1 DDR3 DIMM slot - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 69
. For connecting to Cyclades connection, use ADB2239. For connecting to DB9M connection, use rolled cat5e and digi76000702 or manually wire with Digikey P/N 046-0000-ND. Table 2 Pin out information Item SL390s Serial port DIGI CM RJ-45 Sun RJ-45 Cisco RJ-45 Cyclades RJ-45 1 RTS CTS CTS RTS - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 70
status LED indicators located on the: • Front panel • Rear panel These LED indicators aid in problem diagnosis by indicating the status of system components and operations of the server. Front panel LED indicators The front panel LED indicators allow constant monitoring of basic system functions - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 71
Figure 65 Health LED Indicator location Table 5 Health LED indicator status Components Health LED indicator Status Red(Blinking) Amber (Blinking) Green Off Description Critical system failure detected System degrade System in on and no failure detected System is off and there is no failure - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 72
Components UID LED indicator Status Blue Blue(Blinking) Off Descriptions Identification System is being remotely managed Off Power LED Indicator The power status of the server is indicated by the bicolor LED on the front panel. Connectors, Switches, and LEDs 72 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 73
location Table 7 Power/system health LED indicator status Component Status Description Power/system health LED indicator Steady green The server is operating normally. Steady Amber Steady red Off The server is system off or in hibernation with A/C power. Critical event happens to the - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 74
Figure 68 UID/LED indicator location Table 8 UID/LED indicator states Item Component UID LED indicator Status Blue Blue(Blinking) Off Description Identification System is being remotely managed Off Connectors, Switches, and LEDs 74 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 75
HP ProLiant SL390s G7 2U 3 GPU Server User Guide or the HP website (http://www.hp.com/support/smartstart/documentation). HP Insight Diagnostics HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provide diagnostics and troubleshooting - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 76
to the Management CD in the HP SIM website (http://www.hp.com/go/hpsim). HP Insight Remote Support software HP Insight Remote Support software delivers secure remote support for your HP Servers and Storage, 24 X 7, so you can spend less time solving problems and more time focused on your business - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 77
/advisories and service dispatch. It is optimized for environments with 1 to 50 servers and can be installed on a shared HP ProLiant Windows application server. The software supports HP EVA storage devices, HP ProLiant, BladeSystems, HP Integrity and HP 9000 servers running Microsoft Windows - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 78
Internal SD support An internal SD connector is available for use with embedded Hypervisors. This solution provides for use of a permanently installed SD card in the internal connector, decreasing the possibility of tampering or loss. Diagnostic tools 78 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 79
HP ProLiant SL390s G7 2U server. Specifications include: System Unit Table 9 Hardware Specifications Item Processor socket Processor support System Board Components Intel 1366pin FCLGA Quad-Core Intel® Xeon® Series Processor Intel® Tylersburg 36D /Intel ICH10R iLO3 Intel 82576 Intel®Tylersburg36D - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 80
platform System board dimension Dimensions (H x W x D) (with bezel) Server weight (approximate) Description ATX (Advanced Technology Extended) 17.935''x6.5'' 6. of memory, one hard drive, and one processor 8 trays installed) 58.4kg Table 11 Environmental Specifications Item Description Thermal - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 81
use the Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power% 20Calculator%20Catalog.xls - Click on the system of interest. Example: xxxxxx - Follow the instructions of the next screens. Physical and Operating Specifications 81 - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 82
5 customer self repair (CSR), 5 D diagnostic tools, 74 diagnostics utility, 74 dimensions server, 79 drives back plane, 37 Drives cable management, 32 hard drives, 34 Drives cable connections, 33 E electric shock symbol, 29 warning, 28 F front panel components, 65 G GPU spare part number, 22 H hard - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 83
support, 26 technical support requirements, 26 HP Insight Diagnostics, 74 HP Insight Remote Support software, 75 HP ProLiant Essentials Foundation Pack, 75 HP resources, 74 resources, troubleshooting, 74 S server dimensions rack, 79 server warnings and cautions, 28 SL390s System Board spare part - HP ProLiant SL390s | HP ProLiant SL390s G7 2U half width Server Maintenance and - Page 84
front panel, 65 rear panel, 66 system board components, 67 system tray removing, 30 replacing, 31 System Unit specifications, 78 Systems Insight Manager, 75 T thermal solution, 79 tools, 74 troubleshooting, 74 U USB support, 76 utilities, 74 W warnings battery replacement, 50 PSU replacement, 54
HP ProLiant SL390s G7 2U half width Server
Maintenance and Service Guide
Part number 614097-001
September 2010 (First edition)