- HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 1
HP ProLiant xw2x220c Blade Workstation Maintenance and Service Guide Part Number 518100-001 December 2008 (First Edition) - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 2
or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries. Intended audience This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 3
components 12 Hard drive...13 DIMMs...15 Heatsink...15 Processor ...17 Cache module battery...22 Battery cable ...23 Mezzanine card...24 Workstation A system board...25 Workstation B system board ...31 System battery ...38 Cabling ...40 BBWC battery cabling ...40 Using the HP c-Class Blade SUV - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 4
A DIMM slots ...50 Workstation B DIMM slots ...50 Mezzanine connector definitions ...50 System maintenance switch...51 HP c-Class Blade SUV Cable...51 Specifications ...52 Environmental specifications ...52 Workstation blade specifications...52 Acronyms and abbreviations...53 Index...55 Contents - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 5
, HP requires that an authorized service provider replace the part. These parts are identified as "No" in the Illustrated Parts Catalog. Based on is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 6
Illustrated parts catalog Workstation blade components Item Description 1 Heatsink 2 Processor a) 3.00-GHz Intel® Xeon® model E5450 quad-core processor** b) 2.83-GHz Intel® Xeon® model E5440 quad-core processor* ** c) 2.66-GHz - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 7
5 SATA hard drives a) 250-GB, 2.5-in, 5400-rpm - 460427-001 b) 200-GB, 2.5-in, 5400-rpm* 459617-001 c) 120-GB, 2.5-in, 5400-rpm* 459616-001 6 System battery, lithium, 3V* 234556-001 7 Cache module battery cable* 409125-001 8 Cache module battery* 398648-001 9 HP c-Class Blade SUV - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 8
Workstation Adapter for c-Class BladeSystem h) HP PCIe Mezzanine Pass-thru card 11 Hardware and plastics kit* a) BBWC cable shield b) Cache module battery tray c) Hard drive If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 2Optional-Parts - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 9
• Diagnostics Utility Safety considerations Before performing service procedures, review all the safety information. workstation blade access panel and then install the workstation blade into the enclosure. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 10
non-hot-plug operations, you must power down the workstation blade and/or the system. However, it may be necessary to leave the workstation blade powered up when performing other operations, such as hot-plug installations or troubleshooting. Symbols on equipment The following symbols may be placed - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 11
, auxiliary power is still being provided. To remove all power from the workstation blade, remove the workstation blade from the enclosure. After initiating a virtual power down command, be sure that both workstation A and workstation B are in standby mode by observing that the system power LEDs are - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 12
the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the workstation blade before beginning any installation procedure. Improper grounding can cause ESD - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 13
to remove and install the workstation B assembly can cause the system boards to fail. 5. Engage the threads on jackscrew 1 and tighten six turns clockwise. 6. Engage the threads on jackscrew 2 and tighten fully. 7. Tighten jackscrew 1 fully. Hard drive Removal and replacement procedures 13 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 14
them. To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Remove the hard drive assembly. 5. Remove the hard drive from the carrier. CAUTION: To avoid damage to the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 15
injury from hot surfaces, allow the drives and the internal system components to cool before touching them. To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). Removal and - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 16
spare heatsink. CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in the heatsink. Removal and replacement procedures 16 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 17
workstation B assembly ("Install workstation B assembly" on page 13). 5. Install the workstation blade. Processor WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives installing the heatsink, align the guide pins on the processor retention bracket with the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 18
if the processor is removed from the socket. To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Remove the heatsink. 5. Open the processor retaining latch and the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 19
the spare processor. CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Refer to the workstation blade hood label for specific instructions. Removal and replacement procedures 19 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 20
3. Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool. Removal and replacement procedures 20 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 21
even distribution: CAUTION: Heatsink retaining screws should be tightened in diagonally opposite pairs (in an "X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes in the heatsink. Removal and replacement procedures 21 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 22
. Cache module battery To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Remove the workstation A USB key, if installed. 5. Disconnect the battery cables from the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 23
tray. To replace the component, reverse the removal procedure. Battery cable To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). Removal and replacement procedures 23 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 24
, reverse the removal procedure. Mezzanine card To remove the component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Disconnect any cables connected to the mezzanine card. Removal - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 25
component: 1. Power down the workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Remove the workstation A USB key, if installed. 5. If installed, remove one of the following: o Hard drive (on page 13) o Cache - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 26
10. Open the processor retaining latch and the processor socket retaining bracket. CAUTION: To avoid damage to the processor: • Handle the processor only by the edges. • Do not touch the bottom of the processor, especially the contact area. 11. Using your fingers, remove the processor from the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 27
12. Remove the system board assembly. To replace the system board: 1. Install the spare system board. Be sure the spools on the chassis are fully engaged in the slots in the system board and system board shield. 2. Prepare the processor socket on the spare system board: Removal and replacement - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 28
processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Refer to the workstation blade hood label for specific instructions. CAUTION: Always install the processor parallel to the system board to avoid - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 29
5. Close the processor retaining latch and the processor socket retaining bracket. 6. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab. Allow the alcohol to evaporate before continuing. Removal and replacement procedures 29 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 30
of the following patterns to ensure even distribution: CAUTION: To prevent possible workstation malfunction, route the BBWC battery cable so that it does not become "X" pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment holes - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 31
be used by qualified service personnel. This value should workstation blade (on page 11). 2. Remove the workstation blade (on page 11). 3. Access the internal workstation components (on page 12). 4. Remove the workstation B USB key, if installed. 5. Remove the hard drive, if installed ("Hard drive - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 32
8. Open the processor retaining latch and the processor socket retaining bracket. CAUTION: To avoid damage to the processor: • Handle the processor only by the edges. • Do not touch the bottom of the processor, especially the contact area. 9. Using your fingers, remove the processor from the failed - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 33
10. Remove the heatsink retainer from the workstation B assembly. 11. Remove the system board assembly. To replace the system board: Removal and replacement procedures 33 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 34
1. Install the spare system board. 2. Install the heatsink retainer. 3. Prepare the processor socket on the spare system board: Removal and replacement procedures 34 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 35
processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Refer to the workstation blade hood label for specific instructions. CAUTION: Always install the processor parallel to the system board to avoid - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 36
6. Close the processor retaining latch and the processor socket retaining bracket. 7. Clean the old thermal grease from the heatsink and the top of the processor with the alcohol swab. Allow the alcohol to evaporate before continuing. Removal and replacement procedures 36 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 37
pattern). IMPORTANT: When installing the heatsink, align the guide pins on the processor retention bracket with the alignment Workstation B system board components (on page 49)." 12. Install the workstation B assembly ("Install workstation B assembly" on page 13). 13. Install the workstation blade - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 38
. This option should only be used by qualified service personnel. This value should always match the serial workstation will automatically reboot. System battery HP recommends replacing the battery on both workstation A and workstation B when either battery is replaced. If the workstation blade - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 39
5. Remove the battery. IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU. To replace the component, reverse the removal procedure. Removal and replacement procedures 39 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 40
, see "HP c-Class Blade SUV Cable (on page 51)." Connecting locally to a workstation blade with video and USB devices Use the SUV cable to connect a monitor and any of the following USB devices: • USB hub • USB keyboard • USB mouse • USB CD/DVD-ROM drive • USB diskette drive Numerous configurations - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 41
4 5 6 Description Monitor USB mouse HP c-Class Blade SUV Cable Workstation blade Video connector USB keyboard Accessing a workstation blade with local media devices Use a USB hub when connecting a USB diskette drive and/or USB CD-ROM drive to the workstation blade. The USB hub provides additional - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 42
hub to one USB connector. 4. Connect the following to the USB hub: o USB CD/DVD-ROM drive o USB keyboard o USB mouse o USB diskette Item 1 2 3 4 5 6 7 Description Monitor USB mouse HP c-Class Blade SUV Cable workstation blade USB hub USB keyboard USB CD/DVD-ROM drive or diskette drive Cabling 42 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 43
on ProLiant servers and workstation blades. This guide includes problem-specific flowcharts to help you navigate complex troubleshooting processes. To view the guide, select a language: • English (http://www.hp.com/support/ProLiant_TSG_en) • French (http://www.hp.com/support/ProLiant_TSG_fr - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 44
For more information on ProLiant USB support, refer to the HP website (http://h18004.www1.hp.com/products/servers/platforms/usb-support.html). Internal USB functionality An internal USB connector is available for use with security key devices and USB drive keys. This solution provides for use - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 45
B serial label pull tab Workstation B HP c-Class Blade SUV Cable connector* Workstation blade handle Workstation A HP c-Class Blade SUV Cable connector* Workstation A serial label pull tab Workstation A Power On/Standby button * The SUV connector and the HP c-Class Blade SUV Cable are for some - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 46
Front panel LEDs Item Description 1 Workstation B system power LED 2 Workstation B UID LED 3 Workstation B health LED 4 Workstation B NIC link and activity LED* 5 Workstation A NIC link and activity LED* 6 Workstation A health LED 7 Workstation A UID LED Status Green = On Amber = - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 47
Green = On Amber = Standby (auxiliary power available) Off = No power available to workstation * Actual NIC numbers depend on several factors, including the operating system installed on the workstation blade. Access components CAUTION: The jackscrews control the unseating and seating of critical - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 48
A system board components Item 1 2 3 4 5 6 7 8 9 10 11 12 Description Internal USB connector Hard drive connector Processor socket 1 (populated) Processor socket 2 Workstation A serial number label Signal connector Enclosure connector System maintenance switch Mezzanine connector 1 Mezzanine - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 49
Workstation B system board components Item 1 2 3 4 5 6 7 8 9 Description Hard drive connector Processor socket 2 Processor socket 1 (populated) System maintenance switch System battery Signal connector Workstation B serial number label DIMM slots Internal USB connector Component identification 49 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 50
slots Mezzanine connector definitions Item PCIe support Workstatino support Mezzanine connector 1 x8, Type I mezzanine card only Workstation A only Mezzanine connector 2 x8, Type 1 mezzanine card only Workstation B only A PCIe x8 mezzanine connector supports x16 cards at up to x8 speeds - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 51
and NVRAM. CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the workstation or data loss could occur. HP c-Class Blade SUV Cable Item 1 2 3 4 Connector Workstation blade Video USB Serial Description For connecting to the SUV connector on the - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 52
. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. Workstation blade specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 5.56 cm (2.19 in - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 53
Customer Self Repair FC Fibre Channel HBA host bus adapter HP SIM HP Systems Insight Manager iLO 2 Integrated Lights-Out 2 IML Integrated Management Log PCIe peripheral component interconnect express POST Power-On Self Test RBSU ROM-Based Setup Utility SATA serial ATA SIM Systems Insight Manager UID - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 54
USB universal serial bus Acronyms and abbreviations 54 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 55
43 dimensions, workstation 52 DIMM slot locations 50 DIMM slots 50 DIMMs 15 DVD-ROM drive 9 E electrostatic discharge 9 external cables 40 F front panel components 45 front panel LEDs 46 H hard drive, replacing 13 hard drives 13 heatsink 15 HP c-Class Blade SUV Cable HP Insight Diagnostics 43 - HP ProLiant xw2x220c | HP ProLiant xw2x220c Workstation Blade Maintenance and Se - Page 56
system board battery 38 system board components 48 system components 9, 45 T temperature 52 temperature ranges (environmental) 52 tools 9, 43 troubleshooting 43 troubleshooting guidelines 43 U USB connectors 51 USB devices 40, 41 USB support 44 utilities 43 V video connector 51 W warnings 9 Index 56
HP ProLiant xw2x220c Blade Workstation
Maintenance and Service Guide
Part Number 518100-001
December 2008 (First Edition)