HP Scitex FB550 Scitex FB550 and FB750 Printers- Cleaning Instructions - Page 22
Clean ionizer needles, Proceed
View all HP Scitex FB550 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 22 highlights
4. Remove the screw (A in the figure below) that secures the wiper clamp to the wiper assembly. Figure 20 Service station wiper assembly 5. Separate the two wiper clamp halves and remove the original wiper. 6. Install the replacement wiper blade in the orientation shown below. Figure 21 Wiper, clamp and screw 7. Secure the wiper blade clamp to the wiper assembly using the original screw. 8. To reset the maintenance counter for this task and complete the procedure, press Proceed. Clean ionizer needles CMYKcm - 250 Hours CMYKW - 250 Hours Ink dust and debris can collect on the ionizer needles, which degrades their ability to eliminate static. Cleaning the ionizer needles keeps the ionizer bar in optimal performance. 1. Select from the control panel System> Tools> User Cleaning and Maintenance> 12) Cleaner Ionizer Needles. 2. Press Proceed to continue. The printer moves the rail for easier access to the ionizer bar. 20 User cleaning ENWW