HP StorageWorks 1606 Brocade Converged Enhanced Ethernet Command Reference v6. - Page 207
for each CoS PFC mode. TX_Pause frame generation statistics are always presented for
View all HP StorageWorks 1606 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 207 highlights
show qos flowcontrol interface 11 show qos flowcontrol interface Displays all of the configured flow control information for an interface. Synopsis show qos flowcontrol interface {tengigabitethernet slot/port | linecard slot | portset chip | all} Operands tengigabitethernet Reports QoS flow control statistics for a single 10 Gbps Ethernet interface. slot Specifies the 10 Gbps Ethernet linecard slot number within the chassis. port Specifies the 10 Gbps Ethernet port number within the linecard. linecard portset Reports the QoS flow control statistics for all 10 Gbps Ethernet interfaces within an ASIC. slot Specifies the ASIC linecard slot number within the chassis. chip Specifies the ASIC number within the linecard. all Reports QoS flow control statistics for all interfaces within the system. Command EXEC mode Modes Description Use this command to display all of the configured flow control information for a specific interface. Usage Guidelines Use this command to display the runtime state retrieved from the dataplane reflecting the operation of 802.3x pause or Priority Flow Control (PFC) on an interface. The administrative state for pause generation and reception or processing is presented for the interface (802.3x mode) or for each CoS (PFC mode). TX_Pause frame generation statistics are always presented for the interface. The RX_Pause BitTimes is presented for the interface (802.3x mode) or for each CoS (PFC mode). When PFC is deployed under the CEE Provisioning model, then the command reports whether the Data Center Bridging eXchange protocol (DCBX) has overridden the user configuration, for example when the DCBX detects a mis-configuration between CEE peers, it disables PFC operationally. Examples To display all of the configured flow control information for a 10 Gbps Ethernet interface: switch#show qos flowcontrol interface tengigabitethernet 0/1 Interface TenGigabitEthernet 0/1 Mode PFC DCBX enabled for PFC negotiation TX 0 frames TX TX RX RX Output Paused CoS Admin Oper Admin Oper 512 BitTimes 0 Off Off Off Off 0 1 Off Off Off Off 0 2 On Off On Off 0 3 Off Off Off Off 0 4 Off Off Off Off 0 5 Off Off Off Off 0 6 Off Off Off Off 0 7 Off Off Off Off 0 See Also show qos interface, show cee maps Converged Enhanced Ethernet Command Reference 189 53-1001347-01