HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.1b release notes (5697-764 - Page 18

Additional Port Info column in FC Ports tab in Web Tools shows

Page 18 highlights

Closed defect summary Solution Web Tools event filtering uses a time range of 0-11 rather than 1-12. In Web Tools Fabric Events and Events window, on invoking filter button and filtering based on "from" time or "to" time, on providing a time greater than 12 (e.g. 12:30 PM) will result in an error stating that time should be in range of 0-11. Fixed in Fabric OS 5.3.0 Additional Port Info column in FC Ports tab in Web Tools shows "None (FMS Mode)" instead of "Disabled (FMS Mode)." Fixed in Fabric OS 5.3.0 FR4-18i blades rebooted during firmware commit process per firmwaredownloadstatus output. Process does recover. Fixed in Fabric OS 5.3.0 With EZSwitchSetup, fixed zone can't be configured with all ports designated as storage or hosts. This is correct behavior, but the message displayed does not describe how to correct the misconfiguration should the user attempt to configure in that manner. Fixed in Fabric OS 5.3.0 Error messages occur during IPsec FCIP IO. Fixed in Fabric OS 5.3.0 Incorrect information returned during Request Node Identification Data (RNID) registration. Fixed in Fabric OS 5.3.0 User sees wrong port type after port swap on issuing fwsamshow from CLI, due to port type getting swapped in the SAM Report. Fixed in Fabric OS 5.3.0 Due to current handling of invalid zone type during zone enforcement after failover, Name Server daemon (nsd) panic results in CP fault Fixed in Fabric OS 5.3.0 after firmwaredownload. Unable to view policy details in the absence of IPSEC license from "Show IP Security policies". Fixed in Fabric OS 5.3.0 After changing an expired password and selecting another Admin Domain during the same session, the password expiration message and password prompt are displayed again. Currently have to exit session and re-login after changing an expired password to avoid this issue. Fixed in Fabric OS 5.3.0 Error messages from ACL configuration through SMI are too generic and don't contain sufficient information to debug the problem. Fixed in Fabric OS 5.3.0 Portstats: Selecting the "Show delta" radio button and clicking on the clear counter button, does not clear the counters. It changes the values to negative. Clicking the clear counter button again will reset counter to zero. Fixed in Fabric OS 5.3.0 May see FFDC warning messages when manually changing switch IP address in DHCP network. Fixed in Fabric OS 5.3.0 Able to establish API session to Admin Domain 255 using "user" login which has Admin Domain membership only to Admin Domain 0, which is not allowed from CLI, resulting in error. Users of SMI and Web Tools won't observe error because all operations performed via Admin role user. Fixed in Fabric OS 5.3.0 Web Tools currently not consistent with CLI on nl configuring long distance for ports if current Admin Domain owns them but not switchmembership. nl Port long distance settings are read-only for owned ports on non-owned switches in Web Tools Extended Fabric tab, but editable for owned ports in Web Tools port configuration wizard. Fixed in Fabric OS 5.3.0 SNMP traps repeatedly sent from the switch every 2 seconds when port taken out of a fault state implicitly by removing cable or module. Caused by too many port offline SCNs being sent out during port fault and recover when there is laser fault. Fixed in Fabric OS 5.3.0 18

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Closed defect summary
Solution
Web Tools event
ltering uses a time range of 0-11 rather than 1-12.
In Web Tools Fabric Events and Events window, on invoking
lter
button and
ltering based on “from” time or “to” time, on providing a
time greater than 12 (e.g. 12:30 PM) will result in an error stating
that time should be in range of 0-11.
Fixed in Fabric OS 5.3.0
Additional Port Info column in FC Ports tab in Web Tools shows
"None (FMS Mode)" instead of "Disabled (FMS Mode)."
Fixed in Fabric OS 5.3.0
FR4-18i blades rebooted during
rmware commit process per
firmwaredownloadstatus
output. Process does recover.
Fixed in Fabric OS 5.3.0
With EZSwitchSetup,
xed zone can’t be con
gured with all
ports designated as storage or hosts. This is correct behavior,
but the message displayed does not describe how to correct the
miscon
guration should the user attempt to con
gure in that manner.
Fixed in Fabric OS 5.3.0
Error messages occur during IPsec FCIP IO.
Fixed in Fabric OS 5.3.0
Incorrect information returned during Request Node Identi
cation
Data (RNID) registration.
Fixed in Fabric OS 5.3.0
User sees wrong port type after port swap on issuing
fwsamshow
from CLI, due to port type getting swapped in the SAM Report.
Fixed in Fabric OS 5.3.0
Due to current handling of invalid zone type during zone enforcement
after failover, Name Server daemon (nsd) panic results in CP fault
after
firmwaredownload
.
Fixed in Fabric OS 5.3.0
Unable to view policy details in the absence of IPSEC license from
“Show IP Security policies”.
Fixed in Fabric OS 5.3.0
After changing an expired password and selecting another Admin
Domain during the same session, the password expiration message
and password prompt are displayed again. Currently have to exit
session and re-login after changing an expired password to avoid
this issue.
Fixed in Fabric OS 5.3.0
Error messages from ACL con
guration through SMI are too generic
and don’t contain suf
cient information to debug the problem.
Fixed in Fabric OS 5.3.0
Portstats: Selecting the “Show delta” radio button and clicking on
the clear counter button, does not clear the counters. It changes the
values to negative. Clicking the clear counter button again will reset
counter to zero.
Fixed in Fabric OS 5.3.0
May see FFDC warning messages when manually changing switch IP
address in DHCP network.
Fixed in Fabric OS 5.3.0
Able to establish API session to Admin Domain 255 using “user”
login which has Admin Domain membership only to Admin Domain
0, which is not allowed from CLI, resulting in error. Users of SMI and
Web Tools won’t observe error because all operations performed
via Admin role user.
Fixed in Fabric OS 5.3.0
Web Tools currently not consistent with CLI on
con
guring long distance for ports if current Admin Domain owns
them but not
switchmembership
.
Port long distance settings are read-only for owned ports on
non-owned switches in Web Tools Extended Fabric tab, but editable
for owned ports in Web Tools port con
guration wizard.
Fixed in Fabric OS 5.3.0
SNMP traps repeatedly sent from the switch every 2 seconds when
port taken out of a fault state implicitly by removing cable or module.
Caused by too many port of
ine SCNs being sent out during port
fault and recover when there is laser fault.
Fixed in Fabric OS 5.3.0
18