HP StorageWorks 2/16V HP StorageWorks Fabric OS 5.3.1b release notes (5697-764 - Page 22

Fabric OS 5.3.0a

Page 22 highlights

Fabric OS 5.3.0a fixes Table 4 lists defects closed in the Fabric OS 5.3.0a firmware release. Table 4 Fabric OS 5.3.0a closed defects Closed defect summary Solution Iswitchd panic occurred during data migration with DMM when invalid frame issued to the switch. Fixed in Fabric OS 5.3.0a. Panic occurred on SAN Director 2/128 when running MS commands GPT/GPPN/GPS/GAPNL continuously. Fixed in Fabric OS 5.3.0a. When the 4/64 SAN Switch is constantly rebooted, the Name server crashed in rare conditions. Fixed in Fabric OS 5.3.0a. 4/32B SAN Switch running 5.3.0 rejected GID_Ft command from an HBA with "FC4-type not registered" error. HBA sees no devices. Fixed in Fabric OS 5.3.0a by implementing a more robust zone name check to avoid confusing frame redirection zones with regular zone names. In isolated cases, degraded performance can occur with the Brocade Fabric OS 5.3.0a optimizes certain 4Gb SAN Switch for HP c-Class BladeSystem when internal ports settings in the switch to address this are operated at 4Gb/sec. issue. Unable to configure FCIP tunnels using Web Tools in FOS 5.3.0. FCIP wizard and stand-alone tab support added for near end tunnel configuration with Fabric OS 5.3.0a. In frame redirect mode, GA_NXT query from initiator returns VI PID and PWWN instead of host PWWN. Fixed in Fabric OS 5.3.0a. scpd can crash on rare occasions due to memory leak in NS API/library during NS queries. Fixed in Fabric OS 5.3.0a. In Open mode, when F_Ports are connected to ports 16-47 on the FC4-48 Blade with WWN zoning, the Zone enforcement shows as SESSION BASED and the portcamshow command displays misleading information. Fixed in Fabric OS 5.3.0a. In frame redirect mode, GPN_NN query returns VI PWWN and PID instead of initiator PWWN and PID. Fixed in Fabric OS 5.3.0a. 22

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

Fabric OS 5.3.0a
xes
Table 4
lists defects closed in the Fabric OS 5.3.0a
rmware release.
Table 4 Fabric OS 5.3.0a closed defects
Closed defect summary
Solution
Iswitchd panic occurred during data migration with DMM when
invalid frame issued to the switch.
Fixed in Fabric OS 5.3.0a.
Panic occurred on SAN Director 2/128 when running MS commands
GPT/GPPN/GPS/GAPNL continuously.
Fixed in Fabric OS 5.3.0a.
When the 4/64 SAN Switch is constantly rebooted, the Name server
crashed in rare conditions.
Fixed in Fabric OS 5.3.0a.
4/32B SAN Switch running 5.3.0 rejected
GID_Ft
command from
an HBA with “FC4-type not registered” error. HBA sees no devices.
Fixed in Fabric OS 5.3.0a by
implementing a more robust zone
name check to avoid confusing
frame redirection zones with regular
zone names.
In isolated cases, degraded performance can occur with the Brocade
4Gb SAN Switch for HP c-Class BladeSystem when internal ports
are operated at 4Gb/sec.
Fabric OS 5.3.0a optimizes certain
settings in the switch to address this
issue.
Unable to con
gure FCIP tunnels using Web Tools in FOS 5.3.0.
FCIP wizard and stand-alone tab
support added for near end tunnel
con
guration with Fabric OS 5.3.0a.
In frame redirect mode, GA_NXT query from initiator returns VI PID
and PWWN instead of host PWWN.
Fixed in Fabric OS 5.3.0a.
scpd
can crash on rare occasions due to memory leak in NS
API/library during NS queries.
Fixed in Fabric OS 5.3.0a.
In Open mode, when F_Ports are connected to ports 16-47 on the
FC4-48 Blade with WWN zoning, the Zone enforcement shows
as SESSION BASED and the
portcamshow
command displays
misleading information.
Fixed in Fabric OS 5.3.0a.
In frame redirect mode, GPN_NN query returns VI PWWN and PID
instead of initiator PWWN and PID.
Fixed in Fabric OS 5.3.0a.
22