HP StorageWorks 2/32 SAN switch universal rack mount kit installation addendum
HP StorageWorks 2/32 - SAN Switch Manual
View all HP StorageWorks 2/32 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 2/32 manual content summary:
- HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 1
applies to the following documents: HP StorageWorks SAN Switch 2/32 Installation Guide, Version 4.0.x AA-RTQVB-TE (February 2003) HP StorageWorks SAN Switch 2/16 Installation Guide, Version 3.0.x AA-RR84B-TE (February 2003) HP StorageWorks SAN Switch 2/8 Installation Guide, Version 3.0.x AA-RSB6B-TE - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 2
as shown here: 1. After page 30 in the HP StorageWorks SAN Switch 2/32 Installation Guide 2. After page 29 in the HP StorageWorks SAN Switch 2/16 Installation Guide 3. After page 32 in the HP StorageWorks SAN Switch 2/8 Installation Guide 2 SAN Switch Universal Rack Mount Kit Installation Addendum - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 3
: ■ SAN Switch 2/32, SAN Switch 2/16, or SAN Switch 2/8 ■ Power cables ■ #2 Phillips screwdriver ■ 7/16-inch wrench or socket ■ The SAN Switch Universal Rack Mount Kit rails and rail mounting hardware listed below: (2) Rear mounting brackets HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 4
in a Rack Using the SAN Switch Universal Rack Mount Kit A right inner rail and a right outer rail A left inner rail and a left outer #10 adapter washer (2) 1/4-20 hex nut with captive star lock washer (2) 1/4-inch flat washer 2 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 5
-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and (2) #10 adapter washers as shown in Figure 2. Figure 2: Installing the rear mounting brackets (HP 9000 Series or comparable EIA rack) HP StorageWorks SAN Switch 2/8|16|32 Installation Guide 3 Addendum Pg - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 6
rear mounting brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws and (2) #10 alignment washers as shown in Figure 3. Figure 3: Installing the rear mounting brackets (HP System/e rack-left rear upright) 4 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 7
in a Rack Using the SAN Switch Universal Rack Mount Kit Note: This kit contains both left rails and them. The nuts will be tightened later in step 8. Figure 4: Installing the outer rails (HP 9000 Series or comparable EIA rack) HP StorageWorks SAN Switch 2/8|16|32 Installation Guide 5 Addendum Pg - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 8
lock washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 5. Figure 5: Assembling the outer rails (HP 9000 Series or comparable EIA rack) 6 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 9
required to assemble the inner rails by referring to Table 1. Table 1: Number of screws required to assemble the inner rails Switch SAN Switch 2/32 SAN Switch 2/16 SAN Switch 2/8 Number of #8-32 x 3/16-inch Screws 12 10 14 HP StorageWorks SAN Switch 2/8|16|32 Installation Guide 7 Addendum Pg - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 10
inner with right outer and left inner with left outer. Note that the SAN switch mounts in the rack with its front, the port side, facing the back of the rack. The rear of the switch, the AC side, faces the front of the rack. 8 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 11
Each switch requires a different number of these screws. For example, Figure 7 shows the an inner rail being attached to the SAN Switch 2/16 with five screws. Attaching both inner rails requires ten screws. Figure 7: Assembling the inner rails HP StorageWorks SAN Switch 2/8|16|32 Installation Guide - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 12
not preinstalled on the SAN Switch 2/8, refer to the HP StorageWorks SAN Switch 2/8 Version 3.1.x Installation Guide for complete plenum installation instructions. Figure 8: Assembling the inner rails on a SAN Switch 2/8 with plenum 10 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 13
the switch into a rack (HP 9000 Series or comparable EIA rack) Insert the switch into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers with one on each side. See Figure 9 and Figure 10. HP StorageWorks SAN Switch 2/8|16|32 Installation Guide 11 - HP StorageWorks 2/32 | SAN switch universal rack mount kit installation addendum - Page 14
b. "Connecting AC Power" on page 45 in the HP StorageWorks SAN Switch 2/16 Installation Guide, Version 3.0.x. c. Connecting the power cord in step 8 on page 45 in the HP StorageWorks SAN Switch 2/8 Installation Guide, Version 3.0.x. 12 Addendum Pg HP StorageWorks SAN Switch 2/8|16|32 Installation
addendum
© 2003 Hewlett-Packard Company
AV–RU6YA–TE
Printed in the U.S.A.
March 2003
Product names mentioned herein may be trademarks of their respective companies as reflected by an associated
footnote. The information in this document is subject to change without notice.
This addendum only applies to the following documents:
HP StorageWorks SAN Switch 2/32 Installation Guide, Version 4.0.x
AA–RTQVB–TE (February 2003)
HP StorageWorks SAN Switch 2/16 Installation Guide, Version 3.0.x
AA–RR84B–TE (February 2003)
HP StorageWorks SAN Switch 2/8 Installation Guide, Version 3.0.x
AA–RSB6B–TE (February 2003)
hp
StorageWorks
SAN switch universal rack mount
kit installation
Product Version:
V3.0.x/V4.0.x