HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 30

The port table contains information on the physical ports on a given director., Table 2-6, Port Table

Page 30 highlights

Table 2-5 Sensor Table (cont'd) Object connUnitSensorName connUnitSensorStatus Provides The module name of the FRU, "FAN" or "PWR" The status indicated by the sensor. The values are defined as follows: unknown(1), other(2), ok(3), warning(4), failed(5). connUnitSensorInfo connUnitSensorMessage connUnitSensorType connUnitSensorCharacteristic The value returned is based upon the director FRU status. The active, backup and update-busy states are mapped to ok(3). And the failed state is mapped to failed(5). The serial number of the FRU is returned. No value is returned if the module is failed. The textual description of the FRU status. Either fan(4) or power-supply(5) is returned. The value, other(2), is always returned. The port table contains information on the physical ports on a given director. Table 2-6 Port Table Object *connUnitPortUnitId *connUnitPortIndex connUnitPortType connUnitPortFCClassCap Provides The connUnitId of the director associated with this entry. This table is indexed by this object and the connUnitPortIndex object. The fixed physical port number +1. The index values range from 1 to 32. The value returned will be one of the following: f_port(8), e_port(9), or g_port(10). The value returned is a bit map of the FC class capabilities of the port. For f_port types a constant of 12 (class_two(4) | class_three(8) is returned. For e_port and g_port types 13 is returned (class_f(1) | class_2(4) | class_3(8)) is returned. 24

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

24
±±±±±±±±)LEUH±&KDQQHO±0DQDJHPHQW±0,%
The port table contains information on the physical ports on a given director.
connUnitSensorName
The module name of the FRU,
FAN
or
PWR
connUnitSensorStatus
The status indicated by the sensor. The values are defined as follows:
unknown(1), other(2), ok(3), warning(4), failed(5).
The value returned is based upon the director FRU status. The active, backup
and update-busy states are mapped to ok(3). And the failed state is mapped
to failed(5).
connUnitSensorInfo
The serial number of the FRU is returned. No value is returned if the module is
failed.
connUnitSensorMessage
The textual description of the FRU status.
connUnitSensorType
Either fan(4) or power-supply(5) is returned.
connUnitSensorCharacteristic
The value, other(2), is always returned.
Table 2-6
Port Table
Object
Provides
*connUnitPortUnitId
The connUnitId of the director associated with this entry. This table is indexed
by this object and the connUnitPortIndex object.
*connUnitPortIndex
The fixed physical port number +1. The index values range from 1 to 32.
connUnitPortType
The value returned will be one of the following: f_port(8), e_port(9), or
g_port(10).
connUnitPortFCClassCap
The value returned is a bit map of the FC class capabilities of the port.
For f_port types a constant of 12 (class_two(4) | class_three(8) is returned.
For e_port and g_port types 13 is returned (class_f(1) | class_2(4) |
class_3(8)) is returned.
Table 2-5
Sensor Table (cont
d)
Object
Provides