HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 38

Error Group Table, Capability FcFeCap

Page 38 highlights

• Capability (FcFeCap) The following sections define the FCFE MIB variables and their output. All variables in the FCFE MIB except for fcFxPortPhysAdminStatus, which is defined under fcFxPortPhysTable in fcFeOp group, are read-only. Error Group Table This Fcfporterrrortable displays the number of errors detected by an F_Port since the management agent initialized, enabling you to determine the quality of the link between the F_Port and its attached N_Port. Table 2-13 Error Group Variable Provides the Number of: fcFxPortErrorModuleIndex Module index. fcFxPortErrorPortIndex Port index. LinkFailures Link failures detected by the F_Port. SyncLosses Synchronization losses detected by the F_Port. SignalLosses Signal loss errors detected by the F_Port. PrimSeqProtErrors InvalidTxwords InvalidCRCs DelimiterErrors Primitive sequence protocol errors detected by the F_Port. The number of invalid transmission words detected by the F_Port. The number of invalid cyclic redundancy checks (CRC) detected by the F_Port. Delimiter errors detected by the F_Port. AddressIdErrors LinkResetIns LinkResetOuts OlsIns OlsOutss Address identifier detected by the F_Port. Link reset protocol received by the F_Port from the attached N_Port. Link reset protocol errors issued by the F_Port to the attached N_Port. Offline sequences received by the F_Port. Offline sequences issued by the F_Port. 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

32
±±±±±±±±)LEUH±&KDQQHO±)DEULF±(OHPHQW±0,%±6XSSRUW
Capability (FcFeCap)
The following sections define the FCFE MIB variables and their output. All variables in
the FCFE MIB except for fcFxPortPhysAdminStatus, which is defined under
fcFxPortPhysTable in fcFeOp group, are read-only.
Error Group Table
This
Fcfporterrrortable
displays the number of errors detected by an F_Port since the
management agent initialized, enabling you to determine the quality of the link between
the F_Port and its attached N_Port.
Table 2-13
Error Group
Variable
Provides the Number of:
fcFxPortErrorModuleIndex
Module index.
fcFxPortErrorPortIndex
Port index.
LinkFailures
Link failures detected by the F_Port.
SyncLosses
Synchronization losses detected by the F_Port.
SignalLosses
Signal loss errors detected by the F_Port.
PrimSeqProtErrors
Primitive sequence protocol errors detected by the F_Port.
InvalidTxwords
The number of invalid transmission words detected by the F_Port.
InvalidCRCs
The number of invalid cyclic redundancy checks (CRC) detected by the F_Port.
DelimiterErrors
Delimiter errors detected by the F_Port.
AddressIdErrors
Address identifier detected by the F_Port.
LinkResetIns
Link reset protocol received by the F_Port from the attached N_Port.
LinkResetOuts
Link reset protocol errors issued by the F_Port to the attached N_Port.
OlsIns
Offline sequences received by the F_Port.
OlsOutss
Offline sequences issued by the F_Port.