HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 45

Capability Group Table, Variable, Provides

Page 45 highlights

Variable Medium TxType Distance Table 2-20 Configuration Table (cont'd) Provides: FC-0 medium of the F_Port. FC-0 transmitter type of the F_Port. FC-0 distance range of the F_Port transmitter. Capability Group Table The Fccfportcaptable displays the capabilities of the F_Port within the fabric element. Table 2-21 Capability Group Table Variable Provides CapModuleIndex Module index. FxPortIndex Port index. FC-PHVersionHigh Highest or most recent version of FC-PH that the FxPort is capable of supporting. FC-PHVersLow BBCreditMax BBCreditMin Lowest or earliest version of FC-PH that the F_Port is capable of supporting. Maximum number of receive buffers available for holding a class 1 connect-request, or class 2 or class 3 frames from the attached N_Port. Minimum number of receive buffers available for holding a class 1 connect-request, or class 2 or class 3 frames from the attached N_Port. RxDataFldSzMax Maximum size in bytes of the data field in a frame that the F_Port is capable of receiving from its attached N_Port. RxDataFldSzMin Minimum size in bytes of the data field in a frame that the F_Port is capable of receiving from its attached N_Port. Cos Value indicating the set of classes of service the F_Port is capable of supporting. Intermix Flag indicating if the F_Port is capable of supporting the intermixing of class 2 and class 3 frames during a class 1 connection. This flag is only valid if the port is capable of supporting class 1 service. Fixed at no(2). StackedConMode Value indicating the mode of stacked connect request that the F_Port is capable of supporting. Fixed at none(1). Director SNMP support 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

)LEUH±&KDQQHO±)DEULF±(OHPHQW±0,%±6XSSRUW±±±±±±
39
Director SNMP support
Capability Group Table
The
Fccfportcaptable
displays the capabilities of the F_Port within the fabric element.
Medium
FC-0 medium of the F_Port.
TxType
FC-0 transmitter type of the F_Port.
Distance
FC-0 distance range of the F_Port transmitter.
Table 2-21
Capability Group Table
Variable
Provides
CapModuleIndex
Module index.
FxPortIndex
Port index.
FC-PHVersionHigh
Highest or most recent version of FC-PH that the FxPort is capable of supporting.
FC-PHVersLow
Lowest or earliest version of FC-PH that the F_Port is capable of supporting.
BBCreditMax
Maximum number of receive buffers available for holding a class 1 connect-request, or class 2 or
class 3 frames from the attached N_Port.
BBCreditMin
Minimum number of receive buffers available for holding a class 1 connect-request, or class 2 or
class 3 frames from the attached N_Port.
RxDataFldSzMax
Maximum size in bytes of the data field in a frame that the F_Port is capable of receiving from its
attached N_Port.
RxDataFldSzMin
Minimum size in bytes of the data field in a frame that the F_Port is capable of receiving from its
attached N_Port.
Cos
Value indicating the set of classes of service the F_Port is capable of supporting.
Intermix
Flag indicating if the F_Port is capable of supporting the intermixing of class 2 and class 3
frames during a class 1 connection. This flag is only valid if the port is capable of supporting
class 1 service. Fixed at no(2).
StackedConMode
Value indicating the mode of stacked connect request that the F_Port is capable of supporting.
Fixed at none(1).
Table 2-20
Configuration Table (cont
d)
Variable
Provides: