HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 55

Threshold Alert Group, Generic Traps, coldStart

Page 55 highlights

Threshold Alert Group Table 2-29 Threshold Alerts Table Variable ef6000TAIndex ef6000TAName ef6000TAState ef6000TAType ef6000TAPortType ef6000TAPortList ef6000TAInterval ef6000TATrggerValue ef6000TTADirection ef6000TTATriggerDuration ef6000CTACounter Provides: This object is used to identify which threshold has been triggered. The threshold alert name. The current state of the threshold (enabled=1, disabled=2). The type of the threshold. (throughput=1, counter=2) A threshold can be set on a list of physical port numbers or on all the ports of the specified type (list=1, ePorts=2, fPorts=3, flPorts=4) A bitmap that identifies which ports this threshold alert applies to (only valid when the threshold alert port type = list). The left-most bit represents port 0. The number of minutes in a threshold alert interval. If the alert type is a Throughput Thrreshold Alert, this is the percent of utilization (1-100) required to trigger an alert. If the alert type is a Counter Threshold Alert, this is the counger delta required to trigger an alert. Specifies the throughput direction of the threshold (transmit=1, receive=2, either=3). This only applies when the alert type is Throughput Thrreshold Alert. Specifies the amount of timeduring a threshold alert interval that the trigger must be exceeded before an alert is generated. This only applies when the alert type is Throughput Thrreshold Alert. Specifies statistical counter or counter set to be monitored. This object is not supported in the current release. Generic Traps The following generic traps can be received from the director: • coldStart Reports that the SNMP agent is reinitializing due to a power-on reset. Director SNMP support 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

()²³¸¸¸±3ULYDWH±(QWHUSULVH±0,%±¿HI²³¸¸¸À±±±±±±
49
Director SNMP support
Threshold Alert Group
Generic Traps
The following generic traps can be received from the director:
coldStart
Reports that the SNMP agent is reinitializing due to a power-on reset.
Table 2-29
Threshold Alerts Table
Variable
Provides:
ef6000TAIndex
This object is used to identify which threshold has been triggered.
ef6000TAName
The threshold alert name.
ef6000TAState
The current state of the threshold (enabled=1, disabled=2).
ef6000TAType
The type of the threshold. (throughput=1, counter=2)
ef6000TAPortType
A threshold can be set on a list of physical port numbers or on all the ports of
the specified type (list=1, ePorts=2, fPorts=3, flPorts=4)
ef6000TAPortList
A bitmap that identifies which ports this threshold alert applies to (only valid
when the threshold alert port type = list). The left-most bit represents port 0.
ef6000TAInterval
The number of minutes in a threshold alert interval.
ef6000TATrggerValue
If the alert type is a Throughput Thrreshold Alert, this is the percent of utilization
(1-100) required to trigger an alert. If the alert type is a Counter Threshold Alert,
this is the counger delta required to trigger an alert.
ef6000TTADirection
Specifies the throughput direction of the threshold (transmit=1, receive=2,
either=3). This only applies when the alert type is Throughput Thrreshold Alert.
ef6000TTATriggerDuration
Specifies the amount of timeduring a threshold alert interval that the trigger
must be exceeded before an alert is generated. This only applies when the alert
type is Throughput Thrreshold Alert.
ef6000CTACounter
Specifies statistical counter or counter set to be monitored. This object is not