HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 49
Field Replaceable Unit FRU Group, Table 2-23, FRU Group Table Variables, System Group Variables cont
View all HP Surestore 64 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 49 highlights
Table 2-22 System Group Variables (cont'd) Variable ef6000SysOperStatus ef6000SysState ef6000SysAdmStatus (read-write) Provides: The current operational status of the director. The values are defined as follows: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5). If the edOperStatus of the director is operational, the director is in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4). The desired administrative status of the director. A management station may place the director in a desired state by setting this object accordingly. The desired administrative statuses are online(1) and offline(2). Online means setting the director to be accessible by an external Fibre Channel port, and offline means setting the director to be inaccessible. Field Replaceable Unit (FRU) Group Table 2-23 FRU Group Table Variables Variable ef6000FruCode ef6000FruPosition ef6000FruStatus ef6000FruPartNumber Provides: Field replaceable unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module; fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig; fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed, LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig; fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig. Position of the module. Operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the backup module is used. The update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed. Part number of the module. Director SNMP support 43