HP Surestore 64 HP Surestore Director FC-64 SNMP Support Manual - Page 49

Field Replaceable Unit FRU Group, Table 2-23, FRU Group Table Variables, System Group Variables cont

Page 49 highlights

Table 2-22 System Group Variables (cont'd) Variable ef6000SysOperStatus ef6000SysState ef6000SysAdmStatus (read-write) Provides: The current operational status of the director. The values are defined as follows: operational (1), redundant-failure (2), minor-failure (3), major-failure (4), not-operational (5). If the edOperStatus of the director is operational, the director is in one of the four states: online(1), coming-online(2), offline(3), and going-offline(4). The desired administrative status of the director. A management station may place the director in a desired state by setting this object accordingly. The desired administrative statuses are online(1) and offline(2). Online means setting the director to be accessible by an external Fibre Channel port, and offline means setting the director to be inaccessible. Field Replaceable Unit (FRU) Group Table 2-23 FRU Group Table Variables Variable ef6000FruCode ef6000FruPosition ef6000FruStatus ef6000FruPartNumber Provides: Field replaceable unit. A hardware component of the product that is replaceable as an entire unit. Each module defined in this MIB has a fixed FRU code. The values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module; fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig; fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed, LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig; fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig. Position of the module. Operational status of the module. The active(1) state indicates that the current module is active. The backup(2) state indicates that the backup module is used. The update-busy (3) state indicates that the module is in the updating process. The failed(4) state indicates that the current module is failed. Part number of the module. Director SNMP support 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

()²³¸¸¸±3ULYDWH±(QWHUSULVH±0,%±¿HI²³¸¸¸À±±±±±±
43
Director SNMP support
Field Replaceable Unit (FRU) Group
ef6000SysOperStatus
The current operational status of the director. The values are defined as
follows: operational (1), redundant-failure (2), minor-failure (3), major-failure
(4), not-operational (5).
ef6000SysState
If the
edOperStatus
of the director is operational, the director is in one of the
four states: online(1), coming-online(2), offline(3), and going-offline(4).
ef6000SysAdmStatus
(read-write)
The desired administrative status of the director. A management station may
place the director in a desired state by setting this object accordingly. The
desired administrative statuses are online(1) and offline(2). Online means
setting the director to be accessible by an external Fibre Channel port, and
offline means setting the director to be inaccessible.
Table 2-23
FRU Group Table Variables
Variable
Provides:
ef6000FruCode
Field replaceable unit. A hardware component of the product that is replaceable
as an entire unit. Each module defined in this MIB has a fixed FRU code. The
values are defined as follows: fru-bkplane(1) - backplane; fru-ctp(2) - control
processor card; fru-sbar(3) - serial crossbar; fru-fan2(4) - center fan module;
fru-fan(5) - fan module; fru-power(6) - power supply module; fru-reserved(7) -
reserved (not used); fru-glsl(8) - longwave, single-mode, LC connector, 1 Gig;
fru-gsml(9) - shortwave, multi-mode, LC connector, 1 Gig; fru-gxxl(10) - mixed,
LC connector, 1 Gig; fru-gsfl(11) - SFO pluggable, 1Gig; fru-gsf2(12) - SFO
pluggable, 2 Gig; fru-glsr(13) - longwave, single-mode, MT-RJ connector, 1 Gig;
fru-gsmr(14) - shortwave, multi-mode, MT-RJ connector, 1 Gig; fru-gxxr(15) -
mixed, MT-RJ connector, 1 Gig; fru-fint1(16) - F_Port, internal, 1 Gig.
ef6000FruPosition
Position of the module.
ef6000FruStatus
Operational status of the module. The active(1) state indicates that the current
module is active. The backup(2) state indicates that the backup module is used.
The update-busy (3) state indicates that the module is in the updating process.
The failed(4) state indicates that the current module is failed.
ef6000FruPartNumber
Part number of the module.
Table 2-22
System Group Variables (cont
d)
Variable
Provides: